Start-up
8
First Start-up
Your tiptel 40 VoIP is supplied with the following factory default settings (this is not a
complete list and only gives the settings relating to the initial functional test):
•
The internal S
0
is configured for a Euro-ISDN multi-point connection.
•
The default IP address is set to 192.168.1.111.
•
The DHCP client is not active.
•
The username/password for the web-based configuration is admin/admin.
Note:
The IP address/sub-network mask can also be configured without a
network/PC using an ISDN telephone.
Installing the System
The tiptel 40 VoIP is prepared for wall mounting. The required distance between
screws is 118 mm.
Tools required
•
Percussion drill with 6 mm masonry bit
•
Various screwdriver sizes
•
Side-cutting nipper, strip-insulation pliers, crimping pliers for US-type phone
plugs where applicable
Order of installation
The following sequence must be observed when installing the system:
•
Installation location requirements
•
Wall installation
•
Connecting the terminal (telecom system/ISDN telephone)
•
Connecting the device to the available network
•
Connecting the system to the 230v mains network
Connecting the VoIP/ISDN adapter
1. Mount the adapter in a suitable location.