background image

13.03.2019 | V1.81 

 

8 | 9

  

Overfill Prevention Controller EUS-2 | 

Technical Description  

 

 

 

 

[email protected] 
www.timm-technology.de  

8.

 

International Approvals 

In addition to the 

ATEX

 certificate, we also have Ex-approvals for the EUS-2 according to 

IECEx

 and 

EAC Ex

 (according to TR-CU 012/2011) for Australia, Oceania and the Eurasian cus-

toms union.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Europe (EU + EFTA) 

EC-Type-Examination Certificate 

TÜV 13 ATEX 

132121 

Russia / EAEU 

EAC Ex Certificate according 

to TR ZU 012/2011  

Australia | Oceania 

IECEx Certificate  

 

Summary of Contents for EUS-2

Page 1: ...H Timm Elektronik GmbH Humboldtstr 29 21509 Glinde GERMANY OVERFILL PREVENTION CONTROLLER EUS 2 Technical Description Version 1 81 English...

Page 2: ...n Protection 2 3 3 High Functional Safety Fail Behavior 2 3 4 Bright Signal Light 2 3 5 Graphic Display 2 3 6 Easy Configuration by Joystick 3 3 7 Reliable Ground Verification 3 3 8 Control Outputs Da...

Page 3: ...nnection The level sensors are positioned in the top of each tank compartment deep enough to as sure that once a sensor gets activated product flow stops before the compart ment is completely full In...

Page 4: ...With this unique combination of the types of protection the main housing can be opened in gas hazardous areas when power is switched on for configuration and service e g for setting the additional co...

Page 5: ...e plug and socket connection will be noticed in time for pre ventive measures 3 8 Control Outputs Data Interface Six control outputs enable advanced op tions for connecting the control unit ac cording...

Page 6: ...systems Blue marked plug with three lock ing pins and seven electrical con tacts fitting onto 6 pin truck sock ets for optic vehicle sensor systems acc to API RP 1004 standard The additional 7th pin...

Page 7: ...onal truck socket for detecting the truck connector in park position status by integrated socket code generator 4 3 Testing Equipment The functioning of the control unit can easily get checked by usin...

Page 8: ...functional limitations must be ob served Maximum values Uo 12 7 V Io 129 mA Po 360 mW 5 3 Control Output Circuits Contact Outputs Type of protection Increased safety Ex eb Maximum values 250 V AC 3 A...

Page 9: ...ower supply 1 2 Closing contact output K1 Filling release 3 4 Closing contact output K2 Filling release 5 7 Switching contact output K3 Configurable 8 10 Switching contact output K4 Configurable 15 16...

Page 10: ...s In addition to the ATEX certificate we also have Ex approvals for the EUS 2 according to IECEx and EAC Ex according to TR CU 012 2011 for Australia Oceania and the Eurasian cus toms union Europe EU...

Page 11: ...es or technical support our employees will be glad to be available for you on the following contact information Dr Alexander Zelck Head of international sales 49 40 248 35 63 31 zelck timm technology...