11. Troubleshooting

Problem

•  Lamp stays ON  
  all the time  
  night and day.

Solution

The unit may be suffering from false activation.  

Cover the sensor lens completely with a thick cloth. 

This will prevent the sensor from “seeing” anything.  

If the unit now switches off after the set time duration 

and does not re-activate, this indicates that the 

problem was caused by false activation. The problem 
may be solved by slightly adjusting the direction/angle 

of the sensor head (see previous section).

Check LED status:- If a single LED is constantly visible, 
the unit is in Manual Override Mode and will illuminate 
until dawn or until reset to Automatic Mode. To reset 
to Automatic Mode, switch the internal switch/circuit 

night the process will be repeated, the unit will remain on for this set period  
(0 – 8 hours) and then will operate as a PIR unit until dawn.
•  Switch the internal wall switch/circuit breaker 3 times (off/on off/on off/on) 

within 2 seconds. A single flashing red LED at the top of the sensor head 
indicates Holiday Mode.

•  The unit will now illuminate for a user defined time between 1 and 8 hours.  

The time can be set by rotating the centre adjustment knob as required.  
(See diagram G, the adjustment knob is identified by the letter T inside a circle.)

•  This time adjustment is factory set to 1 hour.
Note: Fully anti-clockwise is 1 hour, fully clockwise is 8 hours.
•  After the defined period has elapsed, the unit will return to Automatic Mode 

and operate as previously set up and the three scrolling LED’s will illuminate 
from left to right.

•  Holiday Mode will NOT reset to Automatic Mode at dawn, it will repeat each 

night until reset by the user.

•  To cancel Holiday Mode, switch the internal wall switch/circuit breaker once 

(OFF/ON) within one second. The unit will turn to Automatic Mode indicated  
by the scrolling LEDs.

Summary of Contents for MLB3000

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 3000W Multi PIR Light Controller Model MLB3000 Black Model MLW3000 White...

Page 2: ...rating of the circuit cable fuse or circuit breaker 3 Technical Specifications 230V AC 50 Hz This PIR is of Class ll Construction and must not be earthed Motion Detection Range Up to 12 metres at a 2...

Page 3: ...the unit so that the sensor looks ACROSS the likely approach path Avoid positioning the sensor where there are any sources of heat in the detection area extractor fans tumble dryer exhausts etc inclu...

Page 4: ...Drill out the mounting holes taking care to avoid any joists electrical cables or water gas pipes that may be hidden beneath the surface Insert the rawl plugs into the holes Diagram D Diagram G Diagra...

Page 5: ...t is not required simply remove from the unit and discard Place the round end of the tether into the keyhole shape location hole on the wall plate Ensure the tether is securely fixed into the slot bef...

Page 6: ...tly and the unit is in Test Mode Adjust the sensor head to the desired direction for best coverage See diagram B Test Mode Three LED s Visible The lamp will now illuminate for approximately 2 seconds...

Page 7: ...The setting is best achieved by the procedure below See diagram G the Dusk adjustment knob is indicated by the Moon and Sun symbols 1 Set the DUSK control knob fully anti clockwise 2 When the ambient...

Page 8: ...d see diagram G This time adjustment is factory set to 1 hour Fully anti clockwise is 1 hour fully clockwise is 8 hours Note If the light is still ON at dawn before the set time expires it will automa...

Page 9: ...n will operate as a PIR unit until dawn Switch the internal wall switch circuit breaker 3 times off on off on off on within 2 seconds A single flashing red LED at the top of the sensor head indicates...

Page 10: ...he warm up period should never exceed 5 minutes Occasionally wind may activate the PIR Also passages between buildings etc can cause a wind tunnel effect Ensure the unit is not positioned so as to all...

Page 11: ...stage charges outside of the UK All shipping costs are to be paid in advance before a replacement is sent The level of ambient light in the area may be too dark for the current DUSK setting During day...

Page 12: ...l csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Suppor...

Reviews: