background image

7

8

HELPLINE

020 8450 0515

Masking the Sensor Lens

•  To restrict the sensor coverage, preventing detection in unwanted areas, mask 

the sensor lens using the masks provided in the accessory pack (see diagram H).

•  The top section of the lens covers long range detection, the bottom covers short 

range. Similarly the left and right lens sections cover the left and right detection 
areas respectively.

Manual Override Mode – Single LED Illuminated

The light can be switched on for longer time periods by use of the Manual  
Override Mode. This can be activated at night by using the internal wall switch  
or circuit breaker.
•  Switch the internal wall switch/circuit breaker twice (OFF/ON, OFF/ON)  

within 2 seconds.

•  The unit will now illuminate continuously for the user defined time,  

between 1 – 8 hours, or until the unit is switched back into auto mode.

•  The ON time can be set by rotating the centre adjustment knob as required  

(see diagram G). This time adjustment is factory set to 1 hour  
(Fully anti-clockwise is 1 hour, fully clockwise is 8 hours).

Note: If the light is still ON at dawn, before the set time expires, it will 
automatically switch OFF.
•  The Manual Override Mode can be setup in the day time or at night time.
•  In the day time, the Manual Override mode is indicated by the permanent 

illumination of a single red LED in the top of the sensor head.

•  At night time, no red LED will be visible.
•  To switch the unit back into Auto Mode, flick the internal wall switch/circuit 

breaker (OFF/ON) once within 1 second. The unit will return to Auto Mode.  
This is indicated by the return of the left to right scrolling LED’s as described  
in Automatic Operation above.

Holiday Mode – Single LED Flashing

The benefit of Holiday Mode is that the user can program the unit automatically 
illuminate for a certain time, (1 – 8 hours) each night. At dusk the unit will 
illuminate for this set period after which it will extinguish. The unit will continue 
to operate normally when it senses movement until dawn. At dusk the following 

Summary of Contents for MLB3000

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 3000W Multi PIR Light Controller Model MLB3000 Black Model MLW3000 White...

Page 2: ...rating of the circuit cable fuse or circuit breaker 3 Technical Specifications 230V AC 50 Hz This PIR is of Class ll Construction and must not be earthed Motion Detection Range Up to 12 metres at a 2...

Page 3: ...the unit so that the sensor looks ACROSS the likely approach path Avoid positioning the sensor where there are any sources of heat in the detection area extractor fans tumble dryer exhausts etc inclu...

Page 4: ...Drill out the mounting holes taking care to avoid any joists electrical cables or water gas pipes that may be hidden beneath the surface Insert the rawl plugs into the holes Diagram D Diagram G Diagra...

Page 5: ...t is not required simply remove from the unit and discard Place the round end of the tether into the keyhole shape location hole on the wall plate Ensure the tether is securely fixed into the slot bef...

Page 6: ...tly and the unit is in Test Mode Adjust the sensor head to the desired direction for best coverage See diagram B Test Mode Three LED s Visible The lamp will now illuminate for approximately 2 seconds...

Page 7: ...The setting is best achieved by the procedure below See diagram G the Dusk adjustment knob is indicated by the Moon and Sun symbols 1 Set the DUSK control knob fully anti clockwise 2 When the ambient...

Page 8: ...d see diagram G This time adjustment is factory set to 1 hour Fully anti clockwise is 1 hour fully clockwise is 8 hours Note If the light is still ON at dawn before the set time expires it will automa...

Page 9: ...n will operate as a PIR unit until dawn Switch the internal wall switch circuit breaker 3 times off on off on off on within 2 seconds A single flashing red LED at the top of the sensor head indicates...

Page 10: ...he warm up period should never exceed 5 minutes Occasionally wind may activate the PIR Also passages between buildings etc can cause a wind tunnel effect Ensure the unit is not positioned so as to all...

Page 11: ...stage charges outside of the UK All shipping costs are to be paid in advance before a replacement is sent The level of ambient light in the area may be too dark for the current DUSK setting During day...

Page 12: ...l csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Suppor...

Reviews: