Dry Contact
w/o 230V AC Potential

16

• Follow the wall 

switch wiring 
image for 
connection.

12. Troubleshooting Guide

PROBLEM 

• Lamp stays  

ON all the time  
night and day.

SOLUTION

Check wiring connections.  
Wires to L and L’ terminals may  
be transposed.

• Lamp stays 

ON all the 
time at night, 
or PIR keeps 
activating at 
random for 
no apparent 
reason

The unit may be suffering from false 
activation. Cover the sensor lens completely 
with black PVC tape. This will prevent the 
sensor from ‘seeing’ anything. If the unit 
now switches off after the set time duration 
and does not re-activate, this indicated that 
the problem was caused by false activation. 
The problem may be solved by slightly 
adjusting the direction/angle of the sensor 
head (see previous section). If however, the 
unit continues to remain ON or to operate 
randomly then the unit is faulty and should 
be replaced.

Summary of Contents for LEDPROFOB

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 2300W PIR Light Controller c w RF Control Model SLB2300RF Black Model SLW2300RF White Model LEDPROFOB RF Remote Fob...

Page 2: ...trician is consulted or used for the installation of this PIR sensor and install in accordance with the current IEE wiring and Building Regulations Check that the total load on the circuit including w...

Page 3: ...nual Override Mode ON OFF operation using RF Remote Fob 6 fobs max Sensor Head Adjustment Pan angle Left right 90 Tilt angle Up 15 Down 60 RF Module RX Receiver RF Frequency 433 92MHz IP55 Rated suita...

Page 4: ...1 2m Total number of fobs usable per PIR 6 Operating Temperature 20 C to 40 C RF Module TX Transmitter RF Frequency 433 72MHz to 434 12MHz IP44 Rated suitable for restricted external applications CE C...

Page 5: ...ee diagram A detailing detection range and direction The light controller is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS see diagram B Therefore position th...

Page 6: ...isolating switch should be installed to enable the power to be switched ON OFF for maintenance purposes During extreme weather conditions the motion light controller may exhibit unusual behaviour Thi...

Page 7: ...Drill the holes ensuring not to infringe with any gas water pipes or electrical cables that may be hidden below the surface Insert the rawl plugs into the holes 6 6 Pass the 230V 50Hz mains supply an...

Page 8: ...late If using a power screwdriver use the lowest torque setting 6 8 Terminate the cables into the terminal block ensuring correct polarity is observed and that all bare conductors are sleeved See sect...

Page 9: ...Diagram Connect the cables to the terminal block as follows Load Switch Live Brown or Red to L1 Neutral Load Blue or Black to N 230V 50Hz Mains Supply Live Supply Brown or Red to L Neutral Supply Blue...

Page 10: ...rds Adjust the light controller to point in the required direction and angle down to limit forward range as required Set the two adjustment controls on the underside of the unit to the following posit...

Page 11: ...ting Up for Automatic Operation Auto Mode When walk tests are complete the unit can be set into Auto Mode The DELAY TIME ADJUST setting controls how long the unit remains illuminated following activat...

Page 12: ...DUSK control a small amount clockwise pausing to try to get the unit to detect and turn the lights under control ON by moving a hand slowly backwards and forwards across the front of the detector len...

Page 13: ...area respectively Mask the PIR Light controllers lens to suit your installation 10 Accessing Terminals After Installation This may be necessary to add further lighting for instance and the following p...

Page 14: ...PIR light controller is functioning correctly and set forAutomatic Operation Auto Mode before you continue Press the centre button that is located on the bottom of the PIR light controller once do not...

Page 15: ...k OFF again each time between presses You cannot pair a 7th fob If attempted the lamp will flash twice to indicate it has not been paired After the last fob press wait for approximately 30 seconds unt...

Page 16: ...rase all RF Remote Fobs from the PIR Light Controller Press and hold the centre button located on the bottom of the PIR light controller for approximately 5 seconds The lamp will flash 5 times This in...

Page 17: ...t reason The unit may be suffering from false activation Cover the sensor lens completely with black PVC tape This will prevent the sensor from seeing anything If the unit now switches off after the s...

Page 18: ...will not operate at night Refer to section 8 Setting Up for DUSK control adjustment Unit activates during the daytime Refer to section 8 Setting Up for DUSK control adjustment You may not be allowing...

Page 19: ...ll cases For all eligible replacements where agreed by Timeguard the customer is responsible for all shipping postage charges outside of the UK All shipping costs are to be paid in advance before a re...

Page 20: ...For a product brochure please contact Qualified Customer Support Co ordinators will be on line to assist in resolving your query If you experience problems do not immediately return the unit to the st...

Reviews: