Dry Contact
w/o 230V AC Potential
16
• Follow the wall
switch wiring
image for
connection.
12. Troubleshooting Guide
PROBLEM
• Lamp stays
ON all the time
night and day.
SOLUTION
Check wiring connections.
Wires to L and L’ terminals may
be transposed.
• Lamp stays
ON all the
time at night,
or PIR keeps
activating at
random for
no apparent
reason
The unit may be suffering from false
activation. Cover the sensor lens completely
with black PVC tape. This will prevent the
sensor from ‘seeing’ anything. If the unit
now switches off after the set time duration
and does not re-activate, this indicated that
the problem was caused by false activation.
The problem may be solved by slightly
adjusting the direction/angle of the sensor
head (see previous section). If however, the
unit continues to remain ON or to operate
randomly then the unit is faulty and should
be replaced.