13

11. RF Remote Fob

Battery

• To access the battery holder,  

remove the back plate from  
the fob as shown in  
the diagram.

Pairing the RF Remote Fob(s) with the PIR  
Light Controller

Note: You must complete the Walk Test Procedure 
before you can pair the devices. The pairing of the 
fob(s) cannot be actioned with the PIR light controller 
set to Test Mode. Make sure the PIR light controller is 
functioning correctly and set for Automatic Operation 
(Auto Mode) before you continue.

• Press the centre button that  

is located on the bottom  
of the PIR light controller once  
(do not press and hold for 
longer than 4 seconds), the 
lamp will flash twice to indicate 
it is ready to pair your fob(s).

10.2 The terminals are now accessible. If adding 

lighting, ensure the unit’s maximum switching load 
rating is not exceeded (see section 3. Technical 
Specifications).

10.3 Re-attach the PIR light controller to the back plate 

pushing firmly into place.

Summary of Contents for LEDPROFOB

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 2300W PIR Light Controller c w RF Control Model SLB2300RF Black Model SLW2300RF White Model LEDPROFOB RF Remote Fob...

Page 2: ...trician is consulted or used for the installation of this PIR sensor and install in accordance with the current IEE wiring and Building Regulations Check that the total load on the circuit including w...

Page 3: ...nual Override Mode ON OFF operation using RF Remote Fob 6 fobs max Sensor Head Adjustment Pan angle Left right 90 Tilt angle Up 15 Down 60 RF Module RX Receiver RF Frequency 433 92MHz IP55 Rated suita...

Page 4: ...1 2m Total number of fobs usable per PIR 6 Operating Temperature 20 C to 40 C RF Module TX Transmitter RF Frequency 433 72MHz to 434 12MHz IP44 Rated suitable for restricted external applications CE C...

Page 5: ...ee diagram A detailing detection range and direction The light controller is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS see diagram B Therefore position th...

Page 6: ...isolating switch should be installed to enable the power to be switched ON OFF for maintenance purposes During extreme weather conditions the motion light controller may exhibit unusual behaviour Thi...

Page 7: ...Drill the holes ensuring not to infringe with any gas water pipes or electrical cables that may be hidden below the surface Insert the rawl plugs into the holes 6 6 Pass the 230V 50Hz mains supply an...

Page 8: ...late If using a power screwdriver use the lowest torque setting 6 8 Terminate the cables into the terminal block ensuring correct polarity is observed and that all bare conductors are sleeved See sect...

Page 9: ...Diagram Connect the cables to the terminal block as follows Load Switch Live Brown or Red to L1 Neutral Load Blue or Black to N 230V 50Hz Mains Supply Live Supply Brown or Red to L Neutral Supply Blue...

Page 10: ...rds Adjust the light controller to point in the required direction and angle down to limit forward range as required Set the two adjustment controls on the underside of the unit to the following posit...

Page 11: ...ting Up for Automatic Operation Auto Mode When walk tests are complete the unit can be set into Auto Mode The DELAY TIME ADJUST setting controls how long the unit remains illuminated following activat...

Page 12: ...DUSK control a small amount clockwise pausing to try to get the unit to detect and turn the lights under control ON by moving a hand slowly backwards and forwards across the front of the detector len...

Page 13: ...area respectively Mask the PIR Light controllers lens to suit your installation 10 Accessing Terminals After Installation This may be necessary to add further lighting for instance and the following p...

Page 14: ...PIR light controller is functioning correctly and set forAutomatic Operation Auto Mode before you continue Press the centre button that is located on the bottom of the PIR light controller once do not...

Page 15: ...k OFF again each time between presses You cannot pair a 7th fob If attempted the lamp will flash twice to indicate it has not been paired After the last fob press wait for approximately 30 seconds unt...

Page 16: ...rase all RF Remote Fobs from the PIR Light Controller Press and hold the centre button located on the bottom of the PIR light controller for approximately 5 seconds The lamp will flash 5 times This in...

Page 17: ...t reason The unit may be suffering from false activation Cover the sensor lens completely with black PVC tape This will prevent the sensor from seeing anything If the unit now switches off after the s...

Page 18: ...will not operate at night Refer to section 8 Setting Up for DUSK control adjustment Unit activates during the daytime Refer to section 8 Setting Up for DUSK control adjustment You may not be allowing...

Page 19: ...ll cases For all eligible replacements where agreed by Timeguard the customer is responsible for all shipping postage charges outside of the UK All shipping costs are to be paid in advance before a re...

Page 20: ...For a product brochure please contact Qualified Customer Support Co ordinators will be on line to assist in resolving your query If you experience problems do not immediately return the unit to the st...

Reviews: