7
w
ww.timberk.com
Electric air conditioner (split system, in set of two units)
Checks before starting:
Make sure that an air filter is installed.
Make sure that air inlet and outlet grilles of the outdoor unit are not
blocked by foreign objects.
Cleaning of air filter
Air filter cleans the air entering the conditioner from dust and foreign
particles. If the filter is contaminated, the conditioner capacity decreases
sharply.
If the conditioner is operated permanently, the filter should be cleaned
once per two weeks.
If the conditioner is installed in a room with dusty atmosphere, then the air
filter should be cleaned more often.
To remove the filter, open the indoor unit panel.
Remove air filters. Clean the filter with a vacuum cleaner or rinse it in clean
water. If the filter is contaminated heavily, clean it with a soft brush and
wash in diluted washing solution, then dry it in a cool place.
While cleaning the filter with the vacuum cleaner, hold it with
contaminated surface up. While washing the filter in water, hold it with
contaminated surface down.
Do not dry the filter in the sun or near a fire.
Set the air filter to initial position and close the panel.
9. TROUBLESHOOTING
Failures and their possible reasons:
D_gjs pc
Possible reason
Actions
Interruptions in power supply
Wait for restoration of power supply
Batteries in the remote control board are low
Replace the batteries
The conditioner does not
work
Time of turning on is set by the timer
Wait till the conditioner turns on by
the timer or cancel the timer setting
The set air temperature is too high or too low Set the air temperature correctly
The air filter is clogged with dust
Clean the air filter
Insufficient cooling or
heating capacity
Foreign objects block the air inlet and return
air grillages of the outdoor unit
Remove foreign objects
A three-minute delay of compressor turning
on
Wait a little
The conditioner works, but
does not cool or heat the
room
The air temperature is set incorrectly
Set the temperature correctly
10.SERVICE LIFE
Service life of the appliance is 10 years provided that the respective
installation and operation rules are observed.
Date of the conditioner manufacture is shown in a serial number of the
device. For more details, please, ask a shop assistant.
11. UTILIZATION RULES
Upon expiration of the service life, the appliance should be utilized in
accordance with norms, regulations and procedures effective in the
place of utilization.
ENGLISH
Summary of Contents for AC TIM 07H S8ML
Page 16: ...18 www timberk com 17 ...