background image

F

AN

AUTO
HIGH
MID
LOW
SWING

TIMER

 

 ON    TIMER

 

 OFF

SLEEP    SUPER    ECO

FEEL

COOL

DRY
FAN

HEAT

SWING

MODE

TIMER

ECO

SUPER

SLEEP

5

w

ww.timberk.com

 

 

Electric air conditioner (split system, in set of two units)

Figure 3. Description of remote control board

16

12

13

20

17

19

14

18

15

* use of particular indicators depends on 
model and series.
** design of indicator symbols may differ 
depending on model and series.

) Power supple indicator

b) Heating mode indicator
c) Cooling mode indicator
d) Temperature indicator 
e) Timer indicator
f) Operation indicator

12.Button «ON/OFF» (Power). Using this button, you may turn the conditioner 
on or off.
13.Buttons «TEMP» (increase/decrease). Using this button, you may set needed 
air temperature indoors.
14.Button «FAN». Using this button, you may select rotation speed of the 
indoor unit fan: «Auto», «High», «Middle», «Low».
In  Auto  mode the fan speed will change automatically. In dry mode the fan 
speed will remain unchanged    Low .

15.Button «SWING». Using this button, you may regulate position of air-
outlet blinds and forward treated air up and down.
16.Button «TIMER». Pressing this button, you may set the time for turning the 
conditioner on and off (set the time by pressing  TEMP" buttons up and 
down). If the conditioner is off, you may set the time for automatic turning 
on in a set time interval. And vice versa, if the conditioner is on, you may set 
the time for automatic turning off. Before activation of the Timer function 
you may specify the needed settings.
17.Button «SUPPER». Using this button, you may turn the turbo mode on and 
off. In this mode the conditioner shows the maximum cooling (in cool mode) 
or heating (in heat mode) capacity.
18.Button «ECO» (Economic). Using this button, you may turn the economic 
mode on and off. In this mode temperature will increase (in cool mode) or 
decrease (in heat mode) slightly   by 2°  from the specified one. 
19.Button «SLEEP» (Night Care). Using this button, you may turn the sleep 
mode on and off. In this mode, if working for cooling, the conditioner will 
increase temperature by 1 °  from the specified one within two hours. If 
working for heating, the conditioner will decrease temperature by 1 °  from 
the specified one within two hours. After 10 hours of operation the 
conditioner will turn off automatically.
20.Button for selection of operating mode   «MODE». Using this button, you 
may select a needed operating mode: AUTO, COOL, DRY, HEAT, FAN.

Indication of the control board display shall correspond to selected modes.

Work with remote control board

Mounting and replacement of batteries: mount two LR03 alkaline batteries, 
according to polarity indicated on the remote control board.
In order to avoid malfunction of the remote control board do not insert used 
batteries or batteries of various types.
If the conditioner is not used for a long time, remove batteries from the 
board or else electrolyte may leak and damage the board.
In normal operation of the conditioner average service life of batteries will be 
about a half-year.
Replace batteries, if command receiving is not confirmed with an audio 
signal, or if the display does not show a sign of command transfer. When 
generating commands from the remote control board, point an IR-radiator at 
a remote-control signal receiver situated on the indoor unit. Hold the remote 
control board at the distance of no more than 8 m from the indoor unit. The 
remote control board will not work, if there are any curtains, doors or other 
things between it and the indoor unit. Protect the board from water and 
exposure to direct sunlight and heat sources. 

ENGLISH

f

Summary of Contents for AC TIM 07H S8ML

Page 1: ...sed without any special advance notices 18 AC TIM 07H S8ML 01 AC TIM 09H S8ML 01 AC TIM 12H S8ML 01 AC TIM 18H S8ML AC TIM 24H S8ML Air conditioner units for indoor installation Air conditioner units for outdoor installation AC TIM 18H S8ML 01 AC TIM 24H S8ML 01 17 Electric air conditioner split system in set of two units ...

Page 2: ...tioner unplug it Cleaning and maintenance should be performed in accordance with instructions of this manual 15 To ensure the effective work of the conditioner operate it in environment described in the present manual 16 Don t use dangerous chemicals for cleaning of the appliance and don t let them on the appliance 17 When removing an air filter don t touch metal parts of the appliance 18 To avoid...

Page 3: ...r unit kg Net dimensions indoor unit mm Net dimensions outdoor unit mm Packing dimensions indoor unit mm Packing dimensions outdoor unit mm AC TIM 07H S8ML AC TIM 07H S8ML AC TIM 07H S8ML 01 7000 2 05 7500 2 2 800 770 220 50 3 6 3 5 430 1415 32 36 50 R410A E D I class IPX0 IPX4 6 2 23 3 7 8 25 3 718x240x180 600x500x232 805 305 255 745x550x353 AC TIM 09H S8ML AC TIM 09H S8ML AC TIM 09H S8ML 01 9000...

Page 4: ...doorinstallation 11 Air intakegrillesoftheoutdoorunit 5 DELIVERYSET Completesetofairconditioner splitsystem includes Conditionerunitforindoorinstallation 1piece Conditionerunitforoutdoorinstallation 1piece Remotecontrolboard 1piece Batteriesforremotecontrolboard 2pcs Usermanual 1piece Guaranteeslip 1piece Packingofindoor installationunit 1piece Packingofoutdoor installationunit 1piece notsupplied ...

Page 5: ...ing this button you may turn the economic mode on and off In this mode temperature will increase in cool mode or decrease in heat mode slightly by 2 from the specified one 19 Button SLEEP Night Care Using this button you may turn the sleep mode on and off In this mode if working for cooling the conditioner will increase temperature by 1 from the specified one within two hours If working for heatin...

Page 6: ...tion of treated air flow ensuring uniform distribution of temperature and the most comfort conditions in the room To change the position of deflectors use the SWING button Beforecleaningunplugtheconditioner Cleaningoftheindoorunitandremotecontrolboard Indoor unit and remote control board should be cleaned with a dry soft cloth Iftheindoorunitistoounclean moistentheclothwithcoldwater It isprohibite...

Page 7: ...anel 9 TROUBLESHOOTING Failures and their possible reasons D _g jsp c Possible reason Actions Interruptions in power supply Wait for restoration of power supply Batteries in the remote control board are low Replace the batteries The conditioner does not work Time of turning on is set by the timer Wait till the conditioner turns on by the timer or cancel the timer setting The set air temperature is...

Page 8: ...8 www timberk om 1 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Timberk 1 2 3 4 5 6 7 8 9 10 11 12 8 8 9 10 10 10 10 11 12 13 13 13 13 14 ...

Page 9: ...55 745x550x353 AC TIM 12H S8ML AC TIM 12H S8ML AC TIM 12H S8ML 01 12000 3 52 12500 3 66 1280 1270 220 50 5 8 5 8 530 2040 34 39 55 R410A D D I IPX0 IPX4 7 0 29 7 8 7 32 8 770x240x180 700x552x256 855 305 255 803x598x380 AC TIM 18H S8ML AC TIM 18H S8ML AC TIM 18H S8ML 01 18000 5 28 18500 5 42 2150 1900 220 50 9 8 8 6 780 2340 44 48 58 R410A E D I IPX0 IPX4 9 3 36 7 11 8 39 6 898x280x202 760x552x256 ...

Page 10: ...10 www timberk om 4 1 5 1 1 1 2 1 1 1 1 6 2 11 10 8 7 9 3 4 2 5 6 1 2 3 4 5 6 7 8 9 10 11 1 2 TEMP 2 3 SET 4 ON OFF Power 1 1 2 3 4 ...

Page 11: ... FEEL COOL DRY FAN HEAT SWING MODE TIMER ECO SUPER SLEEP 11 www timberk om 3 b c d e f 12 ON OFF Power 13 TEMP 14 FAN Auto High Middle Low Auto Low 15 SWING 16 TIMER TEMP 17 SUPER 18 ECO Economic 2 2 19 SLEEP Night Care 1 1 10 20 MODE 16 12 13 20 17 19 14 18 15 f ...

Page 12: ...р режима Автоматически поддерживаемая температура если 20 C то включается режим Обогрева 23 C если 20 C 26 C то включается режим Осушения 18 C если 26 C то включается режим Охлаждения 23 C SUPER TURBO TURBO TIMER TIMER TEMP TIMER TIMER TEMP TIMER SLEEP SLEEP Night Care 1 1 10 Smart Smart Temp 2 2 2 COOL HEAT FAN 1 ON OFF 2 MODE COOL HEAT FAN 3 TEMP ...

Page 13: ...Задана слишком высокая или слишком низкая температура воздуха в помещении Правильно задайте температуру воздуха Воздушный фильтр забит пылью Очистите воздушный фильтр Недостаточная холодо или теплопроизводительность Посторонние предметы загораживают воздухозаборную или воздуховыпускную решетку наружного блока Удалите посторонние предметы Действует трехминутная задержка включения компрессора Немног...

Page 14: ...4 7 495 6044266 7 495 6044266 52161 2 40 2008 51318 14 1 2006 4 51318 14 2 2006 5 7 51317 3 3 2008 51317 3 2 2006 6 7 RUC IL MP18 B 00006 26 01 2012 25 01 2015 TimberkHomeHeatingAppliancescompanyLtd Hamasgerstr 10 Eilat Israel 1 1 606 499 638 26 77 7 495 6275285 ...

Page 15: ...15 www timberk com Electric air conditioner split system in set of two units Timberk Timberk 1 2 3 1 2 3 c 10 4 RU BY KG KZ UA AK TJ OS CIS ...

Page 16: ...18 www timberk com 17 ...

Reviews: