background image

6

ENGLISH

w

ww.timberk.com

 

 

Electric air conditioner (split system, in set of two units)

AUTO mode (SMART)

The auto mode is turned on and off with the use of the button  MODE  on the 

remote control board.

1. While working in the AUTO mode, a microprocessor will automatically select 

COOL, FAN, HEAT or DRY modes based on the difference between actual and 

preset air temperature indoors.

2.  If  the  AUTO  mode  does  not  provide  comfort  conditions,  select  the  mode 

manually. In automatic mode, depending on air temperature in the room, the 

conditioner will select needed temperature parameters of its operation in the 

following order:

7. OPERATING MODES

"SUPER" mode (TURBO)

When  pressing  the  "TURBO"  button  on  the  remote  control  board,  the 

conditioner will start working in turbo mode   for maximum cooling (in cool 

mode) or for maximum heating (in heat mode).

NOTE

If there is a difference between set and actual air temperature in 

DRY mode, the conditioner will automatically turn on in COOL or 

FAN modes.

TIMER mode

Procedure of timing:

 If the conditioner is off, then press the  TIMER  button to activate the automatic 

turning  on.  Pressing  this  button  once  again,  set  the  time  for  turning  the 

conditioner  on  in  the  set  time  interval. To  cancel  the  timer  mode,  press  the 

TIMER  button once again.

If  the  conditioner is  working,  then  press  the  TIMER   button to activate the 

automatic turning off. Pressing this button once again, set the time for turning 

the conditioner off in the set time interval. To cancel the timer mode, press the 

TIMER  button once again.

"SLEEP" mode

Button «SLEEP» (Night Care). Using this button, you may turn the sleep mode on 

and  off.  In  this  mode,  if  working  for  cooling,  the  conditioner  will  increase 

temperature by 1 °  from the specified one within two hours. If working for 

heating, the conditioner will decrease temperature by 1 °  from the specified 

one within two hours. After 10 hours of operation the conditioner will turn off 

automatically.

Regulation of treated air flow direction

Regulating the position of deflectors (blinds), set the direction of treated air 
flow ensuring uniform distribution of temperature and the most comfort 
conditions in the room. To change the position of deflectors, use the "SWING" 
button.

Before cleaning unplug the conditioner.
Cleaning of the indoor unit and remote control board:
Indoor unit and remote control board should be cleaned with a dry soft 
cloth.
If the indoor unit is too unclean, moisten the cloth with cold water.
It  is prohibited to clean the remote control board with moist cloth.
In order to avoid the damage of paint or details of the conditioner, do not 
clean it with brushes and do not leave them on the surface of indoor unit.
In order to avoid the damage of surface or deformation of the conditioner 
details,  do  not  clean  it  with  petrol,  solvents,  cleaning  powders  or  other 
chemically active substances.
Before a sustained interruption in the conditioner work:
Turn the conditioner on for several hours in the FAN mode. It will allow you 
to dry its inner cavities
Unplug  the  conditioner.  Remove  the  batteries  from  the  remote  control 
board. 

8. MAINTENANCE

Smart  mode  allows  changing  threshold  of  switching  from  mode  to  mode. 

During operation in Smart mode you see "-" on the display. Press

 

keys

 

Temp

 +/-. 

"-" 

will

 

change

 

by

 +(-) 2. 

The range shift of this threshold is within -2...+2 of 

default temperatures.

COOL, HEAT and FAN

1. Turn the conditioner on pressing the "ON/OFF" button.

2. Pressing the "MODE" button, select COOL, HEAT or FAN mode manually.

3.  Pressing  the  "TEMP"  button  (up-down),  set  the  desired  air  temperature 

indoors (except for FAN mode).

4.Pressing the "FAN SPEED" button on the remote control board, select the fan 

rotation  speed:  AUTO,  LOW,  MIDDLE,  HIGH,  and  the  conditioner  will  start 

working in accordance with the selected setting. 

In the Smart mode fan speed 

automatically selected

.

5.To turn the conditioner off, press the "ON/OFF" button once again.

In the FAN mode air temperature indoors is not set.

DRY

Turn the conditioner on pressing the "ON/OFF" button. Pressing the "MODE" 

button, select the DRY mode. The conditioner will start working in the set mode. 

To turn the conditioner off, press the "ON/OFF" button once again.

Temperature indoors  

Automatic mode sele ction 

Automatically maintained 

tempe rature 

if <20°

 

then HEAT mode shall be turned on 

23 °

 

if 20°

-

26°

 

then DRY mode shall be turne d on 

18°

 

if > 26°

 

then COOL mode shall be turned on 

23 °

 

Summary of Contents for AC TIM 07H S8ML

Page 1: ...sed without any special advance notices 18 AC TIM 07H S8ML 01 AC TIM 09H S8ML 01 AC TIM 12H S8ML 01 AC TIM 18H S8ML AC TIM 24H S8ML Air conditioner units for indoor installation Air conditioner units for outdoor installation AC TIM 18H S8ML 01 AC TIM 24H S8ML 01 17 Electric air conditioner split system in set of two units ...

Page 2: ...tioner unplug it Cleaning and maintenance should be performed in accordance with instructions of this manual 15 To ensure the effective work of the conditioner operate it in environment described in the present manual 16 Don t use dangerous chemicals for cleaning of the appliance and don t let them on the appliance 17 When removing an air filter don t touch metal parts of the appliance 18 To avoid...

Page 3: ...r unit kg Net dimensions indoor unit mm Net dimensions outdoor unit mm Packing dimensions indoor unit mm Packing dimensions outdoor unit mm AC TIM 07H S8ML AC TIM 07H S8ML AC TIM 07H S8ML 01 7000 2 05 7500 2 2 800 770 220 50 3 6 3 5 430 1415 32 36 50 R410A E D I class IPX0 IPX4 6 2 23 3 7 8 25 3 718x240x180 600x500x232 805 305 255 745x550x353 AC TIM 09H S8ML AC TIM 09H S8ML AC TIM 09H S8ML 01 9000...

Page 4: ...doorinstallation 11 Air intakegrillesoftheoutdoorunit 5 DELIVERYSET Completesetofairconditioner splitsystem includes Conditionerunitforindoorinstallation 1piece Conditionerunitforoutdoorinstallation 1piece Remotecontrolboard 1piece Batteriesforremotecontrolboard 2pcs Usermanual 1piece Guaranteeslip 1piece Packingofindoor installationunit 1piece Packingofoutdoor installationunit 1piece notsupplied ...

Page 5: ...ing this button you may turn the economic mode on and off In this mode temperature will increase in cool mode or decrease in heat mode slightly by 2 from the specified one 19 Button SLEEP Night Care Using this button you may turn the sleep mode on and off In this mode if working for cooling the conditioner will increase temperature by 1 from the specified one within two hours If working for heatin...

Page 6: ...tion of treated air flow ensuring uniform distribution of temperature and the most comfort conditions in the room To change the position of deflectors use the SWING button Beforecleaningunplugtheconditioner Cleaningoftheindoorunitandremotecontrolboard Indoor unit and remote control board should be cleaned with a dry soft cloth Iftheindoorunitistoounclean moistentheclothwithcoldwater It isprohibite...

Page 7: ...anel 9 TROUBLESHOOTING Failures and their possible reasons D _g jsp c Possible reason Actions Interruptions in power supply Wait for restoration of power supply Batteries in the remote control board are low Replace the batteries The conditioner does not work Time of turning on is set by the timer Wait till the conditioner turns on by the timer or cancel the timer setting The set air temperature is...

Page 8: ...8 www timberk om 1 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Timberk 1 2 3 4 5 6 7 8 9 10 11 12 8 8 9 10 10 10 10 11 12 13 13 13 13 14 ...

Page 9: ...55 745x550x353 AC TIM 12H S8ML AC TIM 12H S8ML AC TIM 12H S8ML 01 12000 3 52 12500 3 66 1280 1270 220 50 5 8 5 8 530 2040 34 39 55 R410A D D I IPX0 IPX4 7 0 29 7 8 7 32 8 770x240x180 700x552x256 855 305 255 803x598x380 AC TIM 18H S8ML AC TIM 18H S8ML AC TIM 18H S8ML 01 18000 5 28 18500 5 42 2150 1900 220 50 9 8 8 6 780 2340 44 48 58 R410A E D I IPX0 IPX4 9 3 36 7 11 8 39 6 898x280x202 760x552x256 ...

Page 10: ...10 www timberk om 4 1 5 1 1 1 2 1 1 1 1 6 2 11 10 8 7 9 3 4 2 5 6 1 2 3 4 5 6 7 8 9 10 11 1 2 TEMP 2 3 SET 4 ON OFF Power 1 1 2 3 4 ...

Page 11: ... FEEL COOL DRY FAN HEAT SWING MODE TIMER ECO SUPER SLEEP 11 www timberk om 3 b c d e f 12 ON OFF Power 13 TEMP 14 FAN Auto High Middle Low Auto Low 15 SWING 16 TIMER TEMP 17 SUPER 18 ECO Economic 2 2 19 SLEEP Night Care 1 1 10 20 MODE 16 12 13 20 17 19 14 18 15 f ...

Page 12: ...р режима Автоматически поддерживаемая температура если 20 C то включается режим Обогрева 23 C если 20 C 26 C то включается режим Осушения 18 C если 26 C то включается режим Охлаждения 23 C SUPER TURBO TURBO TIMER TIMER TEMP TIMER TIMER TEMP TIMER SLEEP SLEEP Night Care 1 1 10 Smart Smart Temp 2 2 2 COOL HEAT FAN 1 ON OFF 2 MODE COOL HEAT FAN 3 TEMP ...

Page 13: ...Задана слишком высокая или слишком низкая температура воздуха в помещении Правильно задайте температуру воздуха Воздушный фильтр забит пылью Очистите воздушный фильтр Недостаточная холодо или теплопроизводительность Посторонние предметы загораживают воздухозаборную или воздуховыпускную решетку наружного блока Удалите посторонние предметы Действует трехминутная задержка включения компрессора Немног...

Page 14: ...4 7 495 6044266 7 495 6044266 52161 2 40 2008 51318 14 1 2006 4 51318 14 2 2006 5 7 51317 3 3 2008 51317 3 2 2006 6 7 RUC IL MP18 B 00006 26 01 2012 25 01 2015 TimberkHomeHeatingAppliancescompanyLtd Hamasgerstr 10 Eilat Israel 1 1 606 499 638 26 77 7 495 6275285 ...

Page 15: ...15 www timberk com Electric air conditioner split system in set of two units Timberk Timberk 1 2 3 1 2 3 c 10 4 RU BY KG KZ UA AK TJ OS CIS ...

Page 16: ...18 www timberk com 17 ...

Reviews: