Your air conditioner should be used in such a way

that it is protected from moisture. e.g. condensation,

splashed water, etc. Do not place or store your air
conditioner where it can fall or be pulled into water
or any other liquid. Unplug immediately.

Always transport your air conditioner in a vertical

position and stand on a stable, level surface during
use.
Turn off the product when not in use.

Always contact a qualified person to carry out

repairs. If the supply cord is damaged it must be
repaired by a qualified repairer.
Keep an air path of at least 30cm all around the
unit from walls, furniture and curtains.
If the air conditioner is knocked over during use,
turn off the unit and unplug from the mains supply
immediately.

SAFETY PRECAUTIONS

!

Always do this

Do not operate your air conditioner in a wet room
such as a bathroom or laundry room.
Do not touch the unit with wet or damp hands or
when barefoot.
Do not press the buttons on the control panel with
anything other than your fingers.
Do not remove any fixed covers. Never use this
appliance if it is not working properly, or if it has
been dropped or damaged.
Never use the plug to start and stop the unit.

Always use the switch on the control panel.

Do not cover or obsturct the inlet or outlet grilles.
Do not use hazardous chemicals to clean or come
into contact with the unit. Do not use the unit in the
presence of inflammable substances or vapour such
as alcohol, insecticides, petrol,etc.
Do not allow children to operate the unit
unsupervised.
Do not use this product for functions other than
those described in this instruction manual.

Never do this

Energy Save

Use the unit in the recommended room size.
Locate the unit where furniture cannot obstruct the air flow.
Keep blinds/curtains closed during the sunniest part pf the day.
Keep the filters clean.
Keep doors and windows closed to keep cool air in and warm air out.

Be sure the electrical service is adequate for the model you have chosen. This information can be found
on the serial plate, which is located on the side of the cabinet and behind the grille.
Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is
important. The power cord is equipped with a three-prong grounding plug for protection against shock
hazards.
Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend
to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified
electrician install the proper receptacle.
Ensure the receptacle is accessible after the unit installation.

WARNING

For your safety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove
any prong from the power cord.

WARNING

Electrical Infor mation

Summary of Contents for MPM3-12HRN1-BH9

Page 1: ...OWNER S MANUAL Model MPM3 12HRN1 BH9 Model MPM3 14CRN1 B I 6 PORTABLE AIR CONDITIONER ...

Page 2: ... NOTE 1 SAFETY PRECAUTIONS Always do this 3 Never do this 3 Electrical information 3 Accessories 4 Names of parts 5 Operation panel of the air conditioner 6 Operating condition 10 Location 11 Window kit installation 11 Exhaust hose installation 14 Water drainage 15 Care and maintenance 16 Troubleshooting 17 CARE AND MAINTENANCE TROUBLESHOOTING TIPS OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS ...

Page 3: ...2 ...

Page 4: ...lles Do not use hazardous chemicals to clean or come into contact with the unit Do not use the unit in the presence of inflammable substances or vapour such as alcohol insecticides petrol etc Do not allow children to operate the unit unsupervised Do not use this product for functions other than those described in this instruction manual Never do this Energy Save Use the unit in the recommended roo...

Page 5: ...MODE FAN SPEED SWING TIMER ON ECONOMY ON OFF TIMER OFF RESET LOCK SET TEMPERATURE C FOLLOW ME LED DISPLAY ION TURBO Remote Controller For remote control models only 1pc Battery For remote controller 2 pc IDENTIFICATION OF PARTS Band For bundling the power cord Drain Hose For continuous drainage 1 pc 1 pc Suggested tools for window kit installation 1 Screwdriver medium size Phillips 2 Tape measure ...

Page 6: ...rrying Handle both sides 1 2 3 5 4 1 2 3 4 5 11 10 6 7 8 9 10 11 Air intake Power cord outlet Drain Outlet A Used on dehumidifying operation Drain Outlet B Used on heating operation Air Outlet Air intake Air filter inside 9 6 7 8 NOTE The illustrations are for explanation purposes only The actual shape of the machine you purchased may be slighted different The actual shape should prevail ...

Page 7: ...ting models only The Mode indicator lights illuminate under the different mode settings Fig 4 Used to adjust increasing decreasing temperature settings 1 C 2 F increments in a range of 17 C 62 F to 30 C 88 F Under Auto timer setting press or hold the Up or Down button to change the Auto time by 0 5 hour increments up to 10 hours then at one hour increments up to 24 hours Power switch on off Fan Op...

Page 8: ... codes E1 E2 E3 P1 7 8 9 10 LED Display 11 To activate the Follow Me feature point the remote control towards the unit and press the Follow Me button T If the unit does not receive the Follow Me signal during any 7 minute interval the FOLLOW ME indicator light turns off to indicate the mode has ended he remote display is actual temperature at its location The remote control will send this signal t...

Page 9: ...P MODE LCD DISPLAY MODELS ON OFF auto LCD display window LCD display window auto Timer on indicator Timer off indicator Auto operation indicator Cooling operation indicator Dry operation indicator Heating operation indicator Fan operation indicator Fan speed indicator Low Med Hi Auto No display Sleep operation Turbo display Anion display on some models Auto swing display Follow me indicator on som...

Page 10: ... to select the appropriate operating mode AUTO COOL DRY FAN HEAT Power switch on off MODE button ON OFF button auto HEAT mode is for cooling heating models only 3 TIMERON OFF button Used to initiate the start time stop time program in confuction with buttons AUTO ON AUTO OFF Used to adjust increasing decreasing temperature settings 1 C 2 F increments in a range of 17 C 62 F to 30 C 88 F Under Auto...

Page 11: ... Perform the same operations as above TIMER OFF setting to set the TIMER ON time The starting stopping time is adjustable from 0 0 to 24 When the air conditioner is off Press the TIMER ON OFF button will first activate the TIMER ON setting program Press the TIMER ON OFF button again will activate the TIMER OFF setting program Perform the same operations as above TIMER ON OFF setting to set the sta...

Page 12: ...o roll the unit over objects The unit must be placed within reach of a properly rated grounded socket Never place any obstacles around the air inlet or outlet of the unit Allow at least 30cm of space from the wall for efficient air conditioning Your window kit has been designed to fit most standard Vertical and horizontal window applications However it may be necessary for you to improvise modify ...

Page 13: ...h of window is less than 27 inches Open the window sash and place the window slider kit on the window stool Fig 9 3 Cut the foam seal adhesive type to the proper length and attach it on the top of the window Show as in Fig 10 4 Close the window sash securely against the window 5 Cut the foam seal to an appropriate length and sealing the open gap between the top window sash and outer window sash Sh...

Page 14: ... if the width of window is less than 27 inches Open the window sash and place the window slider kit on the window stool See Fig 13 3 Cut the foam seal adhesive type to the proper length and attach it on the top of the window Show as in Fig 14 4 Close the sliding sash securely against the window 5 Cut the foam seal to an appropriate length and sealing the open gap between the top window sash and ou...

Page 15: ...nsion plugs and wooden screws of Accessories 1 Prepare a hole in the wall Install the wall Exhaust adaptor A onto the wall outside by using 4 expansion plugs and wooden screws be sure to fix thoroughly See Fig 19 2 Attach the Exhaust hose to wall Exhaust adaptor A The exhaust hose can be installed into the wall Fig 19 max 120CM min 30CM Adaptor A Expansion plug position Adaptor cap Note Cover the ...

Page 16: ...mode remove the drain plug B from the back of the unit Fig 21 install the drain connector 5 8 universal female mender with 3 4 hose locally purchased Please refer to Fig 22 When the water level of the bottom tray reaches a predetermined level and the unit stop operation Carefully move the unit to a drain location remove the bottom drain plug and let the water drain away Fig 24 Restart the machine ...

Page 17: ...6 1 Air filter Clean the air filter at least once every two weeks to prevent inferior fan operation because of dust Grasp the filter tab pull the filter out then up Then remove the screw on the side air intake grille pull the filter out See Fig 23 Wash the air filter by immersing it gently in warm water about 40 C 104 F with a neutral detergent Rinse the filter and dry it in a shady place Replace ...

Page 18: ...und is not level or not flat enough The sound comes from the flowing of the refrigerant inside the air conditioner 4 Noisy or vibration 5 Gurgling sound Switch on again after the unit has cool down The automatic over heat protection function When the temperature at the air outlet exceed 70 C 158 F the device will stop O O 3 Power shut off at Heating mode 6 Compressor does not work and the digital ...