32
SHB10 TIKI
Connecting the outdoor temperature sensor
CAUTION
The maximum available heater power in emergency
mode is 3kW.
CAUTION
The temperature on the thermostat must be set ac-
cording to the system requirements. If the tempera-
ture is too high, it can damage the system.
CAUTION
While on emergency mode, it is not possible to heat
hot water.
Settings
The electric additional heat has a maximum power of
9 kW (3x400V). The power is split into 3 steps. The
possible operational power steps are: 3, 6 and 9 kW.
The maximum power step of the immersion heater
can be set using menu 5.1.12.
Electric additional heat- maximum power
Emergency mode
Emergency mode thermostat
When the controller is set to emergency mode (SF1
is set to ) only the most necessary functions are
activated.
• Hot water is not heated.
• Constant temperature in the supply line, more
information in the section Emergency mode ther-
mostat.
The supply temperature in emergency mode is set
using a thermostat (BT30). It should be set accord-
ing to the demands of the heating/cooling circuits in
operation.
The adjustment range is 5 - 65°C. Please note, how-
ever, that for underfloor heating the setting should be
min. 20°C, max. 35-45°C to maintain comfort in the
room and efficient operation of the system.
5
4
3
2
1
SHK 200S/ SHK 200S-6
BT1
BT1
AA3-X6
The outdoor temperature sensor BT1 (included)
should be connected to the SHB 10 unit via terminal
block AA3-X6:1 and AA3-X6:2.
SHB10
Section 6 |
Electrical connections
5
4
3
2
1
SHK 200S/ SHK 200S-6
BT1
BT1
AA3-X6
Connecting the temperature sensor BT25
The temperature sensor BT25 (included) should
be connected to the SHB 10 unit via terminal block
AA3-X6: 5 and AA3-X6: 6. For the location of the sen-
sor, see the section “Connection options”.
SHB10
Connecting the temperature sensor BT6
Connecting the temperature sensor BT7
11
10
9
8
7
SHK 200S/ SHK 200S-6
BT6
BT6
AA3-X6
18
17
16
15
SHK 200S/ SHK 200S-6
BT7
BT7
AA3-X6
The temperature sensor BT6 (included) should be
connected to the SHB 10 unit via terminal block
AA3-X6: 7 and AA3-X6: 8.
The temperature sensor BT7 (included) should be
connected to the SHB 10 unit via terminal block
AA3-X6: 15 and AA3-X6: 16.
SHB10
SHB10
NOTE
The location of the other sensors is available on
page 82.