WARNING: The emergency control can be stopped at any moment by releasing the knob or by
stopping the pump.
Once this emergency manoeuvre has been carried out, the knurled knobs and the tap must be set to
their initial position again in order to resume the operations (in normal position the knobs are
completely unscrewed).
5.7.
Socket for electric tool connection (Optional)
The work platform can be equipped with a socket
(230V Ac) enabling the operator to connect the
electric tools necessary to carry out his
operations.
To activate the electric line (see pictures above)
introduce a cable into the plug connected to the
230V AC 50 Hz mains, with all protections
according to the current standards in force. If
there is the circuit breaker switch (optional), to
activate the electric line set the switch to ON
position. It is advisable to check the earth-leakage
circuit breaker by means of the specially provided
TEST button.
The plugs and sockets equipped on standard
machines comply with EEC standards and can
therefore be used in EU member countries. On
request the machine can be equipped with plugs
and sockets in compliance with local standards or
with particular needs.
Fig. 14
Connect to the power mains having the following features:
▪
Power voltage 230V ± 10%
▪
Frequency 50÷60 Hz
▪
Activated grounding line.
▪
Working protection devices according to current standards in force.
▪
Do not use extension leads exceeding 5 metres to connect to the mains.
▪
Use a cable of suitable section (min 3x2.5 mm
2
).
▪
Do not use rolled-up cables.
5.8.
Fuel level and re-
fuelling (models “ED”, “D”)
Before using the thermic drive power (Diesel engine) check the fuel level in the tank.
This operation is to be carried out by visually checking the fuel level after unscrewing the filler cap.
▪
Visually check the fuel level before starting to work.
▪
Keep the fuel tank and the motor clean.
5.9.
End of work
After stopping the machine according to the instructions given in the previous paragraphs:
▪
Always set the machine to rest position (platform completely lowered).
▪
Press the emergency Stop button on the ground control panel.
▪
Remove the keys from the control panel to prevent unauthorized people from using the machine;
▪
Recharge the battery according to the instructions given in section "Maintenance" (models “E” and
“ED” only).
▪
To fill the tank (if it applies).
Summary of Contents for AIRO A Series
Page 14: ...Use and Maintenance Manual A16 J A18 J Series Page 14...
Page 17: ...Use and Maintenance Manual A16 J A18 J Series Page 17...
Page 20: ...Use and Maintenance Manual A16 J A18 J Series Page 20...
Page 23: ...Use and Maintenance Manual A16 J A18 J Series Page 23...
Page 26: ...Use and Maintenance Manual A16 J A18 J Series Page 26...
Page 29: ...Use and Maintenance Manual A16 J A18 J Series Page 29...
Page 89: ...Use and Maintenance Manual A16 J A18 J Series Page 89...
Page 108: ...Use and Maintenance Manual A16 J A18 J Series Page 108 029 08 144...
Page 109: ...Use and Maintenance Manual A16 J A18 J Series Page 109 029 08 149...
Page 110: ...Use and Maintenance Manual A16 J A18 J Series Page 110 029 08 161...
Page 111: ...Use and Maintenance Manual A16 J A18 J Series Page 111 029 08 171...
Page 112: ...Use and Maintenance Manual A16 J A18 J Series Page 112 029 08 128...
Page 113: ...Use and Maintenance Manual A16 J A18 J Series Page 113 029 08 129...
Page 114: ...Use and Maintenance Manual A16 J A18 J Series Page 114 029 08 150...
Page 115: ...Use and Maintenance Manual A16 J A18 J Series Page 115 029 08 132...
Page 116: ...Use and Maintenance Manual A16 J A18 J Series Page 116 029 08 158...
Page 117: ...Use and Maintenance Manual A16 J A18 J Series Page 117 029 08 148...
Page 118: ...Use and Maintenance Manual A16 J A18 J Series Page 118 029 08 147...
Page 119: ...Use and Maintenance Manual A16 J A18 J Series Page 119...
Page 121: ...Use and Maintenance Manual A16 J A18 J Series Page 121...
Page 123: ...Use and Maintenance Manual A16 J A18 J Series Page 123...