Use and Maintenance Manual
–
A16 J A18 J Series
Page 56
5.5.
Machine stop
5.5.1.
Normal stop
In normal operating conditions:
▪
By releasing the controls the operation is stopped. Stop occurs within a time limit set in the factory, which guarantees
smooth braking.
▪
By releasing the dead-man pedal located on the platform, the operation is immediately stopped. In the event of an
immediate stop, braking is sudden.
5.5.2.
Emergency stop
Should it be necessary, the operator may immediately stop all machine functions on both platform and ground control panel.
On the platform control panel:
▪
press the emergency stop button on the control panel and the machine is turned off.
▪
By releasing the dead-man pedal, the operation is immediately stopped. In the event of an immediate stop, braking is
sudden.
On the ground control panel:
▪
Press the emergency stop button and the machine (all models) and the heat engi
ne (models “D”, “ED”, “EB”) are
stopped.
▪
Press the power emergency stop button (if available
–
“E” models), and the machi
ne power (power circuit cut-out) is
cut-out.
To resume the operations is necessary:
On the platform control panel:
▪
Turn the emergency stop button of 1/4 turn clockwise.
On the ground control panel:
▪
Turn the emergency stop button of 1/4 turn clockwise.
▪
Pull the power circuit emergency stop button (if available) to the outside until it locks in position to power the machine
again.
5.5.3.
Diesel engine stop
In order to stop the Diesel engine:
On the platform control panel:
▪
Turn the starter key antic
lockwise to position “0”.
▪
Otherwise, press the emergency stop button.
On the ground control panel:
▪
Turn the starter key anticlockwise to position “0”.
▪
Otherwise, press the emergency stop button.
Do not stop the motor when the r.p.m. is high. Before stopping the motor wait until the r.p.m. is at the
lowest.
5.5.4.
Stopping the 380V three-phase or 230V single-phase electrical pump (optional)
To stop the electrical pump (optional):
On the platform control panel:
▪
Press the stop button.
▪
Otherwise, press the emergency stop button.
On the ground control panel:
▪
Press the emergency stop button.
Summary of Contents for AIRO A Series
Page 14: ...Use and Maintenance Manual A16 J A18 J Series Page 14...
Page 17: ...Use and Maintenance Manual A16 J A18 J Series Page 17...
Page 20: ...Use and Maintenance Manual A16 J A18 J Series Page 20...
Page 23: ...Use and Maintenance Manual A16 J A18 J Series Page 23...
Page 26: ...Use and Maintenance Manual A16 J A18 J Series Page 26...
Page 29: ...Use and Maintenance Manual A16 J A18 J Series Page 29...
Page 89: ...Use and Maintenance Manual A16 J A18 J Series Page 89...
Page 108: ...Use and Maintenance Manual A16 J A18 J Series Page 108 029 08 144...
Page 109: ...Use and Maintenance Manual A16 J A18 J Series Page 109 029 08 149...
Page 110: ...Use and Maintenance Manual A16 J A18 J Series Page 110 029 08 161...
Page 111: ...Use and Maintenance Manual A16 J A18 J Series Page 111 029 08 171...
Page 112: ...Use and Maintenance Manual A16 J A18 J Series Page 112 029 08 128...
Page 113: ...Use and Maintenance Manual A16 J A18 J Series Page 113 029 08 129...
Page 114: ...Use and Maintenance Manual A16 J A18 J Series Page 114 029 08 150...
Page 115: ...Use and Maintenance Manual A16 J A18 J Series Page 115 029 08 132...
Page 116: ...Use and Maintenance Manual A16 J A18 J Series Page 116 029 08 158...
Page 117: ...Use and Maintenance Manual A16 J A18 J Series Page 117 029 08 148...
Page 118: ...Use and Maintenance Manual A16 J A18 J Series Page 118 029 08 147...
Page 119: ...Use and Maintenance Manual A16 J A18 J Series Page 119...
Page 121: ...Use and Maintenance Manual A16 J A18 J Series Page 121...
Page 123: ...Use and Maintenance Manual A16 J A18 J Series Page 123...