![TigerStop TigerSaw Miter Owner'S Manual Download Page 13](http://html.mh-extra.com/html/tigerstop/tigersaw-miter/tigersaw-miter_owners-manual_1115619013.webp)
7
The TigerSaw Miter uses TigerStop’s advanced interconnect kit (AIK2) to allow combined control of the positioner and the saw.
This allows a greater degree of automation, with benefits to safety and productivity.
Signaling for the AIK2 is routed through the I/O panel (above).
The safety box (right) monitors safety signals and cuts power to the saw
and the positioner when those signals are disrupted.
The kill line (below) is a red cable stretching the entire length of the saw
system, including tables. The kill line switch (below, right) opens a circuit
when the kill line cable is pulled. This provides an additional way to cut
power to the system in an emergency.
Components
Breaking the Safety Chain
The safety chain is a pair of circuits connected to the emergency switches. Triggering any emergency switch opens both
circuits, signaling a relay to quickly cut power to the positioner and the blade.
Integration & Automation
In an emergency, there are two ways to break the safety chain:
1. Push the red E-stop button on the front of the saw (
).
2. Pull the red kill line cable from any position in front of the saw system.
It will not be possible to activate the positioner or the saw blade until the safety chain has been reset.