LP Tank Filling Practices
Any LP gas tank associated with the motor home should never be filled to more than 80% of total
capacity; filling should always be done only when the motor home is leveled. If the motor home is not
level, the tank may be overfilled (i.e., more than 80% of capacity) and, thus, subject the motor home to
possible fire or explosion from resultant uncontrolled gas flows.
LP Gas Regulator
As noted earlier, the LP gas regulator (Figure 3-8) is the “heart” of the LP gas
distribution system. This regulator reduces and controls the pressure of the gas
on the outlet end to provide a constant supply of gas at a constant pressure to
the gas-operated appliances.
The regulator has a vent to relieve excess pressure on the inlet side of the
regulator, should excess pressure develop in the gas tank and connecting gas
line to that regulator inlet. The vent would normally release the excess LP gas
to the atmosphere until the overpressurization condition is eliminated.
This vent should be regularly checked to assure that it is not clogged or obstructed. If that vent is
blocked from normal operation, component or system failures may result. If periodic visual inspection
indicates any sign of corrosion or degradation, contact a qualified service technician to repair the
regulator as soon as possible; DO NOT operate the LP gas system with any faulty component in place.
Occasionally, the inherent moisture in the LP gas can cause a freeze-up of the regulator when the gas
passes through the regulator. The regulator reduces the high pressure of the gas on its inlet side to a
reduced pressure on its outlet side by permitting a controlled expansion of the gas through the
regulator—this gas expansion necessarily cools the gas (by means of the Joule-Thompson effect) and, if
cooled enough, may cause any moisture content to freeze.
Figure 3-5. LP Gas Regulator
Warning
When the motor home is not being used, the main LP gas valve must be turned
“off.” Also, turn “off” the main valve when the LP gas tank is to be refueled to avoid
the possibility of ignition fuel fumes by the pilot lights. All gas valves on the gas-
operated appliances with Direct Spark Ignition (DSI) should also be in the “off”
position during refueling and/or maintenance operations. DO NOT store LP, motor
fuel, propane, butane, or other flammable liquids inside the motor home as these
represent a very real fire hazard and possible threat to life.
Summary of Contents for 2014 Phaeton
Page 6: ... TIFFIN MOTORHOMES PHAETON Chapter 1 GENERAL INFORMATION GENERAL INFORMATION 1 1 ...
Page 25: ... TIFFIN MOTORHOMES PHAETON Chapter 3 HEATING AIR CONDITIONING HEATING AIR CONDITIONING 2 1 ...
Page 56: ... TIFFIN MOTORHOMES PHAETON Chapter 5 CABINETS FURNITURE CABINETS FURNITURE 5 1 ...
Page 60: ... TIFFIN MOTORHOMES PHAETON Chapter 6 STRUCTURAL FEATURES STRUCTURAL FEATURES 6 1 ...
Page 62: ... TIFFIN MOTORHOMES PHAETON Chapter 7 ELECTRICAL FEATURES ELECTRICAL FEATURES 7 1 ...
Page 74: ... TIFFIN MOTORHOMES PHAETON Chapter 8 SLIDE OUT FEATURES SLIDE OUT FEATURES 8 1 ...
Page 78: ... TIFFIN MOTORHOMES PHAETON Chapter 9 EXTERIOR FEATURES EXTERIOR FEATURES 9 1 ...
Page 85: ... TIFFIN MOTORHOMES PHAETON Chapter 10 INTERIOR FEATURES INTERIOR FEATURES 10 1 ...
Page 88: ... TIFFIN MOTORHOMES PHAETON Chapter 11 PLUMBING BATH FIXTURES PLUMBING BATH FIXTURES 11 1 ...
Page 104: ... TIFFIN MOTORHOMES PHAETON Chapter 13 ROUTINE MAINTENANCE ROUTINE MAINTENANCE 13 1 ...
Page 142: ... TIFFIN MOTORHOMES PHAETON Chapter 14 MAINTENANCE DATA CHARTS MAINTENANCE DATA CHARTS 14 1 ...