TiEmme 2WAYS2 Technical Manual Download Page 7

 

 

 

 

 

 

Pag. 7 / 9 DMAN63W0000020-2Ways2 Manual - System100 Hydro STD2  

 

Stove Room T. 

Room Temperature detected by the board [°C] (visible only if 
an input is set as Room Probe) 

Buffer T.  

Buffer tank Temperature [°C] (visible only if 

P26

=2, 3, 4) 

Pressure 

Water Pressure [mbar] 

Air Flow 

Air Flow [cm/s] 

Fan 

Combustion Fan speed [RPM] (visible only if 

P25

=1, 2) 

Auger 

Auger working time [s] (visible only if 

P81

=0) 

Recipe 

Current combustion recipe [nr] (visible only if 

P04

>1) 

Product Code 

Product Code: 537 

FSYSI01000060.0.0  Control board firmware code and version 

FSYSC02000032.0.0  Remote Control firmware code and version 

Manual Load 

The  procedure  activates  the  pellet  manual  loading  with  activation  in  continuous 
modality of the Auger motor. The loading stops automatically after 600 seconds. The 

system must be OFF for the function can be activated 

Cleaning Reset 

Menu to reset the ‘System Maintenance 2’ function. It is visible only if

 T67

>0. 

Settings 

Thermostat Management 
Menu to set the Radio Room thermostat functioning. 

Thermostat Status 

Description 

Enabled 

The Radio Room Thermostat is used by the system 

Disabled 

The system uses the thermostats of the control panel and, on 
the main frame of the display, the value and the image of the 

thermostat will disappear. 

Radio Standby 

Menu to completely switch off the remote control and lower the battery consumption 

Description 

Display 

Push  the  SET  button  to  enable  the  Standby  mode.  To 

turn on the radio again, first push the 

 key and then 

the 

 button twice. 

If  the  function  is  activated,  the  system  uses  the  room 
probe connected to the control board. 
This feature is to be used in case of prolonged non-use 

of the radio terminal. 

 

Time and Date 
Menu to set time and date. 

Description 

Keys 

Display 

Select hours, minutes, year, month and day 

 

 

Enter editing 

SET 

Modify the value 

 

Save 

SET 

Exit 

ESC 

Radio Test 

This Menu is used to test the connection between the radio terminal and the control 
board,  thereby  verifying  the  level  of  the  electromagnetic  pollution.  The  Terminal 
Radio enters  in continuous transmission and  counts the correct and  failed  answers. 

The quality of the signal depends on the number of the errors. 
Change Code 
Code changing allows matching  the remote control  with a specific board,  so that a 

remote  control  is  matched  only  with  a  specific  stove  or  boiler  (thus  permitting  the 
coexistence of different systems in the same area). In order to change the code: 

 

select a code 

 

enter the Learn Menu of the control board and push the set key 

 

push  the  SET  button  on  the  terminal  radio  and  verify  the  result  of  the 

operation 

Contrast Setting 
This Menu allows setting the display contrast 

Description 

Keys 

Display 

Modify the value 

 

 

Set Contrast 

      

 

15 

-

 

Time and Date

 

16:45 

Thursday 

07/02/2016 

Standby 

Radio 

 
 
 

          Enable

 _____ 

Summary of Contents for 2WAYS2

Page 1: ...Pag 1 9DMAN63W0000020 2Ways2 Manual System100 Hydro STD2 Revision Date 11 12 2017 2WAYS2 RADIO CONTROL FOR SYSTEM100 HYDRO STD2 TECHNICAL MANUAL...

Page 2: ...System100 Hydro STD2 SUMMARY 1 INTRODUCTION 3 2 CONTROL PANEL 4 2 1 THE KEYS 4 2 2 THE DISPLAY 4 3 THE MENU 5 3 1 MAIN THERMOSTAT MODIFICATION 6 3 2 USER MENU 6 3 2 1 Chrono Menu 8 3 2 1 1 Chrono Moda...

Page 3: ...oard Warnings The system works on the radio band ISM 433 92MHz The transmission and receiving distance can be reduced in case of a noisy environment other devices as wireless headphones video sender t...

Page 4: ...ff completely the remote control and thus reduce the battery consumption This feature is to be used in case of prolonged non use of remote control If the function is activated the system uses the room...

Page 5: ...notifies that the planned hours of functioning parameter T67 is reached It is necessary to clean the stove or boiler Block Ignition The message appears if the system is turned off during Ignition afte...

Page 6: ...range 7 7 The default value is 0 Heating Management Boiler Thermostat It allows to modify the value of the Boiler Thermostat You can choose the minimum and maximum values by setting the corresponding...

Page 7: ...switch off the remote control and lower the battery consumption Description Display Push the SET button to enable the Standby mode To turn on the radio again first push the key and then the button tw...

Page 8: ...rs Menu Outputs Test Outputs Test Menu Restore Default Value Menu to restore the parameters values set by the manufacturer 3 2 1 Chrono Menu Menu to set the system ignition extinguishing times 3 2 1 1...

Page 9: ...e types of programming are stored separately if for example the Daily modality is set the other modalities are not changed Program Chrono Keys After choosing the favourite program Select the programmi...

Reviews: