TiEmme 2WAYS2 Technical Manual Download Page 4

 

 

 

 

 

 

Pag. 4 / 9 DMAN63W0000020-2Ways2 Manual - System100 Hydro STD2  

 

 

2

 

Control Panel 

 

2.1

 

The Keys 

 

Key 

Function 

Description 

 

On/Off  

Ignition and Extinguishing of the boiler/stove by pushing the button for 

3 seconds 

Unlock 

System Unlock by pushing the key for 3 seconds 

ESC 

Esc 

Menu exit function 

SET 

Set 

Enter in Submenu, modify and save data 

 

Thermostat Modify 

Radio Room Thermostat modification 

Scroll 

Menu 

and 

Submenu 

Scroll Submenu and

 

Menu 

 

Sleeping Mode 

By  pushing  the  button  when  the  display  is  on  the  main  frame,  the 
remote control will continue to work, but the display will switch off. To 

switch on the display push the button again. 

Standby Mode 

By pushing the button for 3 seconds when the main frame is displayed 

,it  is  possible  to  switch  off  completely  the  remote  control  and  thus 
reduce the battery consumption. This feature is to be used in case of 
prolonged non-use of remote control. If the function is activated, the 

system uses the room probe connected to the Controller.  

To switch on the remote control push the button 

 twice. 

 
 

2.2

 

The Display 

 

Pushing the button 

 the display turns on and the main frame appears. 

 

 

 

 

-Errors: 

Er01: Error Safety High Voltage 1. Also with the system Off. 

Er02: Error Safety High Voltage 2. Only if the Combustion Fan is On. 
Er03: Extinguishing for exhaust under temperature. 

Er05: Extinguishing for exhaust over temperature. 
Er06: Pellet Thermostat open (backfire in the brazier) 
Er07: Encoder Error. No Encoder signal. 

Er08: Encoder Error. Combustion Fan regulation failed. 
Er11: Real time clock error, day and time not correct due to prolonged absence of power supply 

Er12: Extinguishing for Ignition failed. 
Er15: Lack of voltage supply. 

Er17: Air Flow Regulator error. 

Summary of Contents for 2WAYS2

Page 1: ...Pag 1 9DMAN63W0000020 2Ways2 Manual System100 Hydro STD2 Revision Date 11 12 2017 2WAYS2 RADIO CONTROL FOR SYSTEM100 HYDRO STD2 TECHNICAL MANUAL...

Page 2: ...System100 Hydro STD2 SUMMARY 1 INTRODUCTION 3 2 CONTROL PANEL 4 2 1 THE KEYS 4 2 2 THE DISPLAY 4 3 THE MENU 5 3 1 MAIN THERMOSTAT MODIFICATION 6 3 2 USER MENU 6 3 2 1 Chrono Menu 8 3 2 1 1 Chrono Moda...

Page 3: ...oard Warnings The system works on the radio band ISM 433 92MHz The transmission and receiving distance can be reduced in case of a noisy environment other devices as wireless headphones video sender t...

Page 4: ...ff completely the remote control and thus reduce the battery consumption This feature is to be used in case of prolonged non use of remote control If the function is activated the system uses the room...

Page 5: ...notifies that the planned hours of functioning parameter T67 is reached It is necessary to clean the stove or boiler Block Ignition The message appears if the system is turned off during Ignition afte...

Page 6: ...range 7 7 The default value is 0 Heating Management Boiler Thermostat It allows to modify the value of the Boiler Thermostat You can choose the minimum and maximum values by setting the corresponding...

Page 7: ...switch off the remote control and lower the battery consumption Description Display Push the SET button to enable the Standby mode To turn on the radio again first push the key and then the button tw...

Page 8: ...rs Menu Outputs Test Outputs Test Menu Restore Default Value Menu to restore the parameters values set by the manufacturer 3 2 1 Chrono Menu Menu to set the system ignition extinguishing times 3 2 1 1...

Page 9: ...e types of programming are stored separately if for example the Daily modality is set the other modalities are not changed Program Chrono Keys After choosing the favourite program Select the programmi...

Reviews: