Pag. 6 / 9 DMAN63W0000020-2Ways2 Manual - System100 Hydro STD2
3.1
Main Thermostat Modification
Use the buttons
to change the Radio
Room Thermostat value (it is possible only if it
has not been disabled in the specific Menu).
The value can be modified using the same
buttons, save data occurs automatically at the exit
of Menu or pushing SET key.
3.2
User Menu
MENU
DESCRIPTION
Combustion
Management
Power
It allows to modify the combustion power of the system in Pellet mode. It can be set
in automatic or manual mode. In the first case, the system chooses the combustion
power. In the second case, the user selects the desired power. On the left side of the
display is signalled the combustion modality (
A
=automatic combustion,
M
=manual
combustion) and the working power level of the system.
Recipe
Menu to select the combustion recipe. The maximum value is the number of recipes
visible to the user (parameter
P04
). If
P04
=1 the Menu is not visible.
Auger Calibration
It allows to modify the default value of the Auger’s speed and On Times. The values
are in the range – 7 ÷ 7. The default value is 0.
Fan Calibration
It allows to modify the default value of the Combustion Fan speed. The values are in
the range – 7 ÷ 7. The default value is 0.
Heating
Management
Boiler Thermostat
It allows to modify the value of the Boiler Thermostat. You can choose the minimum
and maximum values by setting the corresponding thermostats
T26
and
T27
.
Buffer tank Thermostat
It allows to modify the value of the Buffer tank Thermostat. It will be visible only if
you select a plumbing plant including a Buffer Probe (
P26
=2, 3, 4).
Heating Power
It allows to change the power of the fan heating. This menu is visible only by setting
an output configurable to 6 and
A04
=0. You can set the management of the heating
system in automatic or manual mode.
Heating
Description
0FF
Heating fan is stopped (it is possible only if
P95
=0)
1–Power user
number
Power is adjusted manually from 1 to the maximum number of
power user (parameter
P03
)
Auto
Power is adjusted automatically according to the value of the
parameter
P06
Stove Room Thermostat
It allows to modify the value of the Local Room Thermostat. It is visible only if a
configurable input is set as Room Probe.
Summer-Winter
The user may select between Summer-Winter mode.
Chrono
Menu to select the Chrono Program modality and to set the time of
Ignition/Extinguishing of the boiler/stove.
For more details please see section 3.2.1.
Monitor
This Menu shows some System data of interest
Display
Description
Exhaust T.
Exhaust temperature [°C]
Termostato
Ambiente Radio
Set:
20
°C