3.1

 

Main Thermostat Modification 

 
 

Use  the  buttons 

  to  change  the  Radio 

Room  Thermostat  value  (it  is  possible  only  if  it 
has not been disabled in the specific Menu).  

The  value  can  be  modified  using  the  same 
buttons, save data occurs automatically at the exit 
of Menu or pushing SET key. 

 

 

 

 

3.2

 

User Menu 

 

MENU 

DESCRIPTION 

Combustion 
Management
 

Power 

It allows to modify the combustion power of the system in Pellet mode. It can be set 
in automatic or manual mode. In the first case, the system chooses the combustion 

power. In the second case, the user selects the desired power. On the left side of the 
display  is  signalled  the  combustion  modality  (

A

=automatic  combustion, 

M

=manual 

combustion) and the working power level of the system. 
Recipe 
Menu to select the combustion recipe. The maximum value is the number of recipes 

visible to the user (parameter 

P04

). If 

P04

=1 the Menu is not visible. 

Auger Calibration 
It allows to modify the default value of the Auger’s speed and On Times. The values 

are in the range – 7 ÷ 7. The default value is 0. 
Fan Calibration  
It allows to modify the default value of the Combustion Fan speed. The values are in 

the range – 7 ÷ 7. The default value is 0. 

Heating 
Management 

Boiler Thermostat 
It allows to modify the value of the Boiler Thermostat. You can choose the minimum 

and maximum values by setting the corresponding thermostats 

T26

 and 

T27

. 

Buffer tank Thermostat 
It allows to modify the value of the Buffer tank  Thermostat. It will be visible only if 

you select a plumbing plant including a Buffer Probe (

P26

=2, 3, 4). 

Heating Power 
It allows to change the power of the fan heating. This menu is visible only by setting 

an output configurable to 6 and 

A04

=0. You can set the management of the heating 

system in automatic or manual mode. 

 

Heating

 

Description

 

0FF 

Heating fan is stopped (it is possible only if 

P95

=0) 

1–Power user 

number 

Power is adjusted manually from 1 to the maximum number of 
power user (parameter 

P03

) 

Auto 

Power is adjusted automatically according to the value of the 
parameter 

P06

 

Stove Room Thermostat 

It  allows  to  modify  the  value  of  the  Local  Room  Thermostat.  It  is  visible  only  if  a 
configurable input is set as Room Probe. 
Summer-Winter
 

The user may select between Summer-Winter mode. 

Chrono 

Menu  to  select  the  Chrono  Program  modality  and  to  set  the  time  of 
Ignition/Extinguishing of the boiler/stove. 

For more details please see section 3.2.1. 

Monitor 

This Menu shows some System data of interest 

Display 

Description 

Exhaust T. 

Exhaust temperature [°C] 

 

Termostato  

Ambiente Radio  

 
 
 
 
 
 
 
 

 

 

Set:       

20

°C

 

 

Summary of Contents for 2WAYS2

Page 1: ...Pag 1 9DMAN63W0000020 2Ways2 Manual System100 Hydro STD2 Revision Date 11 12 2017 2WAYS2 RADIO CONTROL FOR SYSTEM100 HYDRO STD2 TECHNICAL MANUAL...

Page 2: ...System100 Hydro STD2 SUMMARY 1 INTRODUCTION 3 2 CONTROL PANEL 4 2 1 THE KEYS 4 2 2 THE DISPLAY 4 3 THE MENU 5 3 1 MAIN THERMOSTAT MODIFICATION 6 3 2 USER MENU 6 3 2 1 Chrono Menu 8 3 2 1 1 Chrono Moda...

Page 3: ...oard Warnings The system works on the radio band ISM 433 92MHz The transmission and receiving distance can be reduced in case of a noisy environment other devices as wireless headphones video sender t...

Page 4: ...ff completely the remote control and thus reduce the battery consumption This feature is to be used in case of prolonged non use of remote control If the function is activated the system uses the room...

Page 5: ...notifies that the planned hours of functioning parameter T67 is reached It is necessary to clean the stove or boiler Block Ignition The message appears if the system is turned off during Ignition afte...

Page 6: ...range 7 7 The default value is 0 Heating Management Boiler Thermostat It allows to modify the value of the Boiler Thermostat You can choose the minimum and maximum values by setting the corresponding...

Page 7: ...switch off the remote control and lower the battery consumption Description Display Push the SET button to enable the Standby mode To turn on the radio again first push the key and then the button tw...

Page 8: ...rs Menu Outputs Test Outputs Test Menu Restore Default Value Menu to restore the parameters values set by the manufacturer 3 2 1 Chrono Menu Menu to set the system ignition extinguishing times 3 2 1 1...

Page 9: ...e types of programming are stored separately if for example the Daily modality is set the other modalities are not changed Program Chrono Keys After choosing the favourite program Select the programmi...

Reviews: