Installing the Power Supply Unit and Charger
P1, P2, P3 and P4 for DC input from SAILOR 6080
These connectors are used for DC input from the installed SAILOR 6080 units
to the Power Supply Unit and Charger.
For instructions how to connect DC input from an additional SAILOR 6080
when upgrading, see Upgrading with additional SAILOR 6080 units on
page 47.
Cross link interface (X8) when sharing a battery
If several Power Supply Unit and Charger units (in primary and duplicated
segments) are installed and share the same battery, you must connect them in
order to control the charging load for the shared battery. This ensures
dynamic adjustments to the requirements for charging the battery and all DC
outputs. The cross link ensures that the maximum charging current is not
exceeded.
The maximum charging current and the float voltage can be configured, for
further details see Customizing battery settings on page 33.
For cross link use NMEA 2000 cables with color coding that match the colors
at the Cross Link connector.
1
Connecting SAILOR 6080
Connector
SAILOR 6081
P1
SAILOR 6081 + 1 SAILOR 6080
P1 + P2
SAILOR 6081 + 2 SAILOR 6080
P1 + P2 + P3
SAILOR 6081 + 3 SAILOR 6080
P1 + P2 + P3 + P4
1.
You may also use Ethernet cable, but then the color coding will not match the
text on the print board. For CAN_H and CAN_L use a twisted pair.
Summary of Contents for Sailor 6081
Page 1: ...INSTALLATION USER MANUAL SAILOR 6081 Power Supply Unit and Charger ...
Page 39: ...Chapter 3 Service and repair 32 Returning units for repair ...
Page 43: ...Chapter 4 Customizing battery settings 36 Changing battery settings ...
Page 61: ...Appendix B Upgrade 54 Upgrading with additional SAILOR 6080 units ...
Page 63: ...Appendix C Approvals 56 Wheelmark ...
Page 68: ...98 130980 A Thrane Thrane A S info thrane com www thrane com ...