7
(1)
Directive 2006/42/EC, annexe 1, point 1.7.4.2 letter u)
L
pA
= weighted continuous acoustic pressure level equivalent.
L
pCPeak
= maximum value of the weighted acoustic displacement pressure at the work place.
L
WA
= acoustic power level emitted by the machine.
(2)
(Directive 2006/42/EC, annexe 1, point 2.2.1.1)
Weighted root mean square in frequency of the acceleration the upper limbs are exposed to for each biodynamic
reference axis. Tests carried out in compliance with the indications contained in UNI ENV 25349 and UNI EN 28662
part 1st Standards, and under operating conditions much more severe than those normally found.
1. GENERAL CHARACTERISTICS
ENGLISH
B1300-UC B1300-UCE
B1300-UCT
B1300-UCA
Application range
suitable for installing electrical compression connectors
for conductors up to 400 mm
2
(800 MCM) and Aluminium
conductors up to 300 mm
2
(600 MCM)
Rated crimping force
kN (US sh. ton)
132 (14.84)
Minimum crimping force
kN (US sh. ton)
125,2 (14.07)
Minimum operating pressure
bar (psi)
692 (10037)
Dimensions (ref. to Fig. 6)
mm (inches)
423 x 239 x 102,5 (16.6 x 9.4 x 4)
Weight with battery
kg (lbs)
6,5 (14.3)
Motor V
DC
18
Operating temperature
°C (°F)
-15 to +50 (+5 to +122)
Recommended oil
AGIP ARNICA 32 or equivalents
Operating speed
twin speed operation and automatic switching from
a rapid advancing speed of the ram to a slower, more
powerful crimping speed
Safety
maximum pressure valve
Rechargeable battery
V / Ah / Wh
18 / 4.0 / 72
Type
CB1840L (Li-Ion)
Weight
kg (lbs)
0,66 (1.45)
Battery charger
ASC30-36
Input
type
EU
27044000
UK
27045000
AUS/NZ
27047000
USA/CAN
27046000
V / Hz
220 - 240 / 50 - 60
115 / 60
W
85
Acoustic noise
(1)
L
pA
dB (A)
66,9
L
pCPeak
dB (C)
86,9
L
WA
dB (A)
74,9
Vibration
(2)
m/s
2
0.398 max.