Problem
kinds
Check part
or point
Possible Cause
Probable Correction
The body
is
electrified
Earth line
The earth line isn't in the
socket.
Please use the socket meeting the
standard.
Lines
The lines are creepage.
Adjust, reconnect /replace lines
Electric
component
The electric component is
creepage,
Replace this electric component.
Scales
occur
frequently
inside the
machine
the water
quality
The rigidity of the water
quality is too high.
Using a water-soften apparatus
installed in front of the water inlet.
Noise
during
operation
is big
Spring of the
internal
compressor
The spring of the internal
compressor drops.
Replace the compressor.
Water pump
The noise of the water pump
Replace the water pump.
Pipeline
system
Pipeline system resonate
Clear pipeline system
Feet
The feet are not leveled
Level and lock the feet.
Fan motor
The fan motor loose, the
clearance of the rotor is
bigger, the fan blade turns
back
Relocate the fan motor / replace
Problem
kinds
Check part
or point
Possible Cause
Probable Correction
Water is
leaking out
the unit
The operation
A few water drops to the floor
when you open the door to
take out ice from ice storage
bin.
Normal condensation on the door or
some water together with ice. Take
care when you take out ice.
Water supply
connection
Water supply connection
leaking.
Tighten fitting.
Water line
Some water line leaks.
Plug into again.
The water
distributio
n tube
doesn't
spray
Lines of the
water pump
The lines of the water pump
loose.
Plug into again
Water pump
Water pump damages
Replace water pump.
Water
distribution
tube
The water distribution tube
blocks
Clean the water distribution tube
Ice full probe
The ice full probe is broken
or can not turn back normal
position.
Repair or replace the probe
The room
temperature
The room temperature is out
the stated range, the water
pump stop
Make the temperature returns within
the stated range.
Hot gas valve
The hot gas valve is poor,
Replace the hot gas valve
The hot gas valve damage
Replace the hot gas valve
15