Floater valve
The floater valve leaks. Lead
to few ice produced.
Repair or replace
3.Ice size is abnormal
Problem
kinds
Check part
or point
Possible Cause
Probable Correction
Cubes are
too small
Condenser
The condenser is dirty or the
air grills are covered
Clean the condenser. Leave space
around the machine
The ambient
temperature
The ambient temperature is
too high.
Adjust the ambient temperature.
Electronic
controller
The setting temperature is
high.
See the service manual "adjust the size
of ice cubes"
Refrigerant
Refrigerant leaks
Recharge.
Cubes are
too big
Electronic
controller
The setting temperature of
Electronic controller is low.
See the service manual "adjust the size
of ice cubes"
Sensor
Temperature sensor of the
evaporator damages
Replace the sensor of temperature.
The ambient
and water
temperature
The ambient temperature and
water temperature is too low.
Adjust the temperature.
The cubes
are
partially
formed--
have
ragged
sides
Water quality
The water quality is poor
Using a water-soften / filter apparatus
installed in front of the water inlet
valve.
Evaporator
Ice machine is dirty
Clean and sanitize the ice machine
Water
distribution
tube
The water distribution tube
blocks
partially
Clean the water distribution tube
The room
temperature
The room temperature is out
the stated range, the water
pump stop
Make the temperature returns within
the stated range.
The ice
cubes
shape
deformity
Filter
Water filtration element needs
to be changed
Replace the filter
Water trough
Water trough level is too low
Adjust the water floater
Cubes are
partially
formed—
are white
at the
bottom
The room
temperature
The room temperature is out
the stated range, the water
pump stop automatically.
Make the temperature returns within
the stated range.
Water trough
Water trough level is too low
Adjust the water floater
4.Other problems