First issue 09 / 03
5
Charged Section
The places where the commercial AC power is used without passing through the power supply transformer. If the places are touched,
there is a risk of electric shock. In addition, the measuring equipment can be damaged if it is connected to the GND of the charged
section and the GND of the non-charged section while connecting the set directly to the commercial AC power supply. Therefore, be
sure to connect the set via an insulated transformer and supply the current.
1. AC Power Cord
2. AC Inlet with Filter
3. Power Switch (S1)
4. Fuse (In the SW POWER SUPPLY Module)
5. Standby Transformer and Converter Transformer (In the SW POWER SUPPLY Module)
6. Other primary side of the SW POWER SUPPLY Module
High Voltage Generating Point
The places where voltage is 100V or more except for the charged places described above. If the places are touched, there is a risk of
electric shock.
1. SW POWER SUPPLY Module . . . . . . . . . . . . . . . . . . (225V)
5. SCAN (B) Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . (355V)
2. X DRIVE Assembly . . . . . . . . . . . . . . . . . . . (–300V to 225V)
6. X CONNECTOR (A) Assembly . . . . . . . . . . . (–300V to 225V)
3. Y DRIVE Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . (355V)
7. X CONNECTOR (B) Assembly . . . . . . . . . . .(–300V to 225V)
4. SCAN (A) Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . (355V)
X DRIVE
Assy
X CONNECTOR (B)
Assy
AC Inlet with Filter
Power Cord
Power Switch
(S1)
Y DRIVE
Assy
SCAN (A)
Assy
SCAN (B)
Assy
X CONNECTOR (A)
Assy
SW POWER SUPPLY
Module
Top
Front
Charged Section and High Voltage Generating Point (Rear View)
: Part is the High Voltage Generating Points
other than the Charged Section.
: Part is Charged Section.