37
First issue 09 /03
ADJUSTMENTS
V-SUS adjustment
1. Turn on the unit.
2. Enter Factory mode.
FAY
3. Set the V-SUS value to that indicated on the Panel Identification label.
RFY
VSU (Value indicated on the Panel Identification label)
4. Check the V-SUS adjustment value.
GAJ: To read the V-SUS value from the output data
5. Finish making adjustments.
FST
FAN
6. Turn off the unit.
V-OFS adjustment
1. Turn on the unit.
2. Enter Factory mode.
FAY
3. Set the V-OFFSET (V-OFS) value to that indicated on the Panel Identification label.
RFY
VOF (Value indicated on the Panel Identification label)
4. Check the V-OFS adjustment value.
GAJ: To read the V-OFS value from the output data
5. Finish making adjustments.
FST
FAN
6. Turn off the unit.
Panel-White-Balance Adjustment
Input signal
Use the MASK 04 signal of the PDP.
Adjustment parameters
PANEL R HIGH/PANEL G HIGH/PANEL B HIGH
PANEL R LOW/PANEL G LOW/PANEL B LOW
Adjustment method
1. Turn on the unit.
2. Adjust the following parameters:
FAY
DIN
M04 the Mask window for adjustment is displayed.
F60
PT1
AB2
GPW Check the parameters before adjustment.
PRHxxx
PGHxxx
PBHxxx
PRLxxx
PBLxxx
PGLxxx
GPW Check the parameters before adjustment.
F50
PT2
AB3
GPW Check the parameters before adjustment.
Adjust the parameters so that the
values of the left and right windows
become those shown in the table below.
(xxx : 0 to 255)