23
First issue 09 /03
ADJUSTMENTS
Adjusting Mode
SERVICE MODE
In this mode, picture-quality adjustments more accurate than those made on the normal user menu and various functions for
alleviating phosphor burn can be performed.
In order to use this mode, you should make PDP the stand-alone. (Or it recommends removing a communication cable with FEB.)
And PDP is made standby (OFF). (Light Emitting Diode must be red lighting.)
The following operations are made into turn in order to go into this menu:
1. It pushes “VOLUME UP” of BODY key first.
2. Next, it pushes “VOLUME DOWN” of Body key.
3. Finally it pushes “POWER ON” of BODY key.
It is necessary to perform these operations quickly. All operations need to carry out within 3 seconds.
If it puts into service mode, a display will come out to the upper left, “SERVICE MODE”(SERVICE MENU).
Operation of a service menu can be performed by the remote control that outputs the Thomson code. And the body key can operate
it also.
To select category (Picture, Screen and etc.), press LEFT or RIGHT key.
Moving a cursor with UP or DOWN key will highlight items (CONTRAST, BRIGHTNESS and etc.). To chose an item, press OK key.
When operating it by the body key, it is the same as menu operation in PC mode at the time of FEB connection.
To escape from a service menu display, press EXIT or MENU key.
Notes:
A service menu does not escape from the mode, even if a signal is lost. (Action differs from the menu for users.) In this case, only
OPTION can be operated.
Again, when a signal is inputted, it is the PICTURE MENU.
Power-Standby mode
Normal Operation mode
: Indicates each mode.
SERVICE MODE
FACTORY MODE
: Indicates a key operation on the remote control unit or the operation panel of the unit.
: Indicates an operation performed with an RS-232C command.
POWER
POWER
Within 3 seconds
MENU
MENU
<FAN>
<FAY>
<AJY>
MENU
<AJN>
ADJUSTMENT MODE