Filter change and disposal:
Take out hygiene box, close intake opening with the hinged cap.
Open front cover above waste bin and dispose of filter. Insert ano-
ther HEPA bag and close front cover. Undo hinged cap of the intake
opening and put back the hygiene box.
1.
2.
3.
Sucking up liquids
Information for use
You can suck up spilled, non-hazardous liquids on water basis
(for example water, coffee, etc.) with the THOMAS HYGIENE
PLUS T2.
•
Caution!
Petrol, thinners, heating oil, etc., can develop explosive
vapours and mixtures if mixed with the intake air.
•
Acetone, acids and solvents can attack the materials used in the
production of the appliance. Both clean and waste water can be
sucked up without any hesitation.
•
Clean and dry the waste water tank and all the parts used after
sucking up liquids.
•
Never suck up liquids without the waste water tank.
•
Your THOMAS HYGIENE PLUS T2 is not suitable for sucking up
larger quantities of liquid from containers or basins.
•
Empty and clean the appliance every time it is used for wet
cleaning.
Waste water and moist parts propagate the growth of
bacteria and fungi (see cleaning and maintenance instructions).
Getting the appliance going:
Take the hygiene box out of the appliance resp. pull the AQUA-filter
by its handle out of the waste water tank, and insert the anti-splash
grid. Also take the HEPA filter out of the appliance.
Insert the anti-splash grid and waste water tank in the appliance.
Make sure that both the wet filter (13a) and the motor protection filter
(15) are fitted.
Connect up suction hose.
Choose a suitable nozzle and fit it on the suction pipe or hand grip,
respectively.
Pull out the mains plug from the appliance and connect up to the
power supply.
Switch on the appliance and set for maximum suction power.
Make sure that the mechanical suction power controller (26) is com-
pletely closed.
Hold the suction tube and hose upwards at an angle for a few
seconds while the motor is still running to prevent the liquid still in the
suction tube for running back into the appliance during a break in use.
Switch off the appliance afterwards.
The float in the waste water tank automatically interrupts the
sucking up operation if the waste water tank is full (you can
clearly hear this from the higher running speed of the motor).
Switch off appliance, disconnect the mains plug and empty the
waste water tank.
Cleaning and care
Only carry out cleaning and servicing operations with the appliance
switched off and disconnected mains plug.
After sucking up liquid
Please use a moist soft cloth to clean the housing. Do not use
any scouring cleaning agent or solvent.
Empty the waste water tank.
Wash the anti-splash grid, waste water tank and wet filter with
clean and possibly warm water.
Check the motor protection filter for contamination and, if
necessary, clean under flowing water and renew if necessary.
Always keep the float (13b) in the waste water tank clean
and serviceable. It interrupts the sucking operation if the waste
water tank is full.
Dry any spray water in the suction space with a soft cloth.
Remove any dirt on the intake connection and on the inside of
the housing cover.
•
The housing cover can be removed from the appliance to make
cleaning easier.
To do this open the cover and swing up vertically. Press the cover
forwards until it slides out of the hinge. Afterwards lift off the cover
upwards.
•
Insert the housing cover vertically and close to lock it in position.
The cover automatically engages in the hinge.
Dry the appliance and accessory parts thoroughly after cleaning.
Wash cleaning
Information for use
•
Caution!
Petrol, thinners, heating oil, etc., can develop explosive
vapours and mixtures if mixed with the intake air.
•
Acetone, acids and solvents can attack the materials used in the
production of the appliance. Both clean and waste water can be
sucked up without any hesitation.
•
After sucking up liquids always clean and dry the waste water tank
and all the parts used.
•
Never suck up liquids without the waste water tank.
•
Your THOMAS HYGIENE PLUS T2 is not suitable for sucking up
larger quantities of liquid from containers or basins.
•
Caution!
Never operate the pump without liquid.
•
Always empty and clean the appliance every time it is used for
wash cleaning. Waste water and moist parts propagate the growth
of bacteria and fungi (see cleaning and maintenance instructions).