Symptom
Remedy
The unit does not work, no light.
Check the mains connection and the main fuse.
No response to the DMX con‐
troller.
1. If the unit is in DMX mode and a DMX controller is
connected and turned on, the
‘d’
flashes in the first posi‐
tion of the display. If not, no valid DMX signal is received.
Check that the DMX controller is switched on. Check the
DMX connectors and cables for proper connection.
2. If the display is not flashing and there is still no
response, check the address settings and DMX polarity.
3. Try using another DMX controller.
4. Check to see if the DMX cables run near or alongside
to high voltage cables that may cause damage or inter‐
ference to DMX interface circuits.
No response to the remote con‐
trol
1. Try the remote control at a different angle to the
receiver on the front of the device.
2. Move the remote control closer to the unit.
3. Check the remote control battery.
Troubleshooting
LED PAR
48
Summary of Contents for Stairville Tri Flat PAR Profile 18x3W RGB
Page 1: ...Tri Flat PAR Profile 5 3W RGB LED PAR user manual...
Page 20: ...6 Connections and operating elements Overview Connections and operating elements LED PAR 20...
Page 22: ...Top side Connections and operating elements LED PAR 22...
Page 24: ...Bottom side Connections and operating elements LED PAR 24...
Page 26: ...Side mounted operating ele ments Connections and operating elements LED PAR 26...
Page 28: ...Remote control Connections and operating elements LED PAR 28...
Page 37: ...7 3 Menu overview Operating Tri Flat PAR Profile 5 3W RGB 37...
Page 53: ...Notes Tri Flat PAR Profile 5 3W RGB 53...
Page 54: ...Notes LED PAR 54...
Page 55: ......
Page 56: ...Musikhaus Thomann e K Treppendorf 30 96138 Burgebrach Germany www thomann de...