8.
Maintenance
8-3
KRF
8. Maintenance
8-6
Method for supplying grease
[KRF3]
The following figure shows a KRF representative greasing method for your reference.
Procedure
1. Move the table to the motor mounting side, place it on the stopper, and then move it back by 50
mm to the reverse motor side.
Place it on the stopper
Motor side
Move it back by
about 50 mm
2. Remove the table cover.
Table cover
Model number
Bolt size
KRF3
M2.6 × 4L
Thin head FH type head screws
3. Remove the springs (2 pcs.).
Spring
* Be careful not to lose the springs.