7-5
KRF
7. Installation and Operation
7.
Installation and Operation
7. Installation and Operation
3. When mounting the intermediate flang
e to h
ousing A after mounting the motor onto the
intermediate flange
Mount the motor onto the intermediate flange.
Motors for mounting and bolt sizes are shown in the following table.
Mounting bolt
Model number
Motor models
Bolt size
Tightening torque [N·cm]
KRF3
SGMMV-A2A (Yaskawa Electric Corporation)
M2.6 × 8L
68
KRF4
TS4602 (Tamagawa Seiki Co., Ltd.)
M4 × 12L
329
KRF5
TS4602 (Tamagawa Seiki Co., Ltd.)
M4 × 12L
329
KRF6
TS4603 (Tamagawa Seiki Co., Ltd.)
M4 × 10L
329
Bolt type: Hexagonal-s
ocket-head type bo
lt
4. Mount the part assembled in procedure 3
o
nto the housing A.
Intermediate flange types and bolt sizes are shown in the following table.
Mounting bolt
Model number
Intermediate flange type
Bolt size
Tightening torque [N·cm]
KRF3
M,N,S
M2.5 × 10L
30
KRF4
P,Q,R,S,M,N
M3 × 15L
125
KRF5
P,Q,R,S,M,N
M3 × 16L
125
KRF6
R
M3 × 16L
125
Bolt type: Hexagonal-s
ocket-head type bo
lt