ModuLam 130 Operators Manual
page 4
Functions and Operation
Soft-touch
©
Control Panel
A. Indicator lamps
Specific lamps are illuminated to indicate the state of one or more of the operating parameters of the
laminator.
Temperature Indicator
– displays the target operating temperature. Also used to
display the current fusion roll temperature when the MEASURE function is selected.
Roller Speed Indicator
– displays the current “running speed” of the lamination
rollers
COLD
Indicates that the current chosen pre-set function is COLD (room temperature)
lamination. (temp. = RT , speed = 2 )
MEAS
Indicates that the MEASURE (MEAS) function has been selected and the
temperature indicator is displaying the current temperature of the fusion rollers.
PREHT
Indicates that the PRE-HEAT (PREHT) function has been selected. (temp. = 80°C,
speed = 2 )
HOT
Indicates that the HOT function has been selected. (temp. = 90°C, speed = 5)
MOUNT
Indicates that the MOUNTING (MOUNT) function is selected. (temp. = 130°C,
speed = 1)
CARRI
Indicates that the MATTING (MOUNT) function is selected. (temp. = 110°C, speed
= 2)
READY
Indicates the state of the rollers. Changes state according to the temperature of the
rollers as follows:
OFF – the temperature of the fusion rollers is below the set point
BLINKING – the temperature of the fusion rollers is above the set point
ON – the temperature of the fusion rollers is at the set point (+/- 3°C)