Activating Temperature Curve
If you have just finished specifying the points on the curve:
Press the push-button once again. The word
OFF
flashes on the
display.
Turn the adjustment knob clockwise one notch. The word
ON
flashes on the display and the Temperature Curve Pilot Light
turns on, indicating that the temperature curve is now activated.
Set the selection knob to
ROOM TEMPERATURE
.
If you have previously defined the points on the curve:
Set the selection knob to
SET POINT / T
o
CURVE
. The current
value of the temperature set point flashes on the display.
Press the push-button. The word
OFF
is displayed.
Press the push-button to display the points of the curve currently
defined until the word
OFF
appears (thirteen clicks).
Turn the adjustment knob clockwise one notch. The word
ON
flashes on the display and the Temperature Curve Pilot Light
turns on, indicating that the temperature curve is now activated.
Set the selection knob to
ROOM TEMPERATURE
.