SERVICE AND MAINTENANCE
25
8.4.
Maintenance intervals
8.4.1.
Daily maintenance
The pressure of the network must be daily verified to be within the allowed limits. Make sure
that all the safety devices and pumps function properly.
8.4.2.
Weekly maintenance
The pellet burner must be cleaned according to the manufacturer’s instructions, usually
recommended once a week. The boiler must also be cleaned every 7-15 days, depending on the
ash quantity accumulated on the boiler walls and in the heat exchanger. Cleaning procedure
must be performed according to the instruction given in the corresponding paragraph.
Check the quantity of ash accumulated in the ash box. The ash disposal can be performed every
2-3 weeks, depending on the ash quantity formed.
8.4.3.
Monthly maintenance
Check the doors and the sealing cord. Make sure the contact with the boiler is air-tight. If ash
has accumulated on the sealing cord, clean it.
Remove the turbinators from the heat exchanger and check their condition.
It is recommended that you clean the chimney box of the boiler and the chimney pipes at least
every 3-4 months, in order to assure efficient and safe function of the boiler.
8.5.
Basic service procedures
8.5.1.
Service after overheating
If overheating occurs, the safety valves of the boiler must open.
Make sure the boiler pump is working. In case of blackout open all the valves of the system to
let hot water out of the boiler. In any case a blackout protection UPS is recommended to be
installed on the boiler pump.
If the chimney damper is not fully opened, put it in fully open position.
All safety devices must lead to drainage! After overheating, make sure that all the water from
the safety devices has drained, and the system has filled with cold water. Check the pressure
and the temperature of the boiler.
At overheating, the safety thermostat will activate, and cut electrical supply to the fan. In that
case, you need to manually reset the safety thermostat and put the system back in function.
Unscrew the plastic cover of the safety thermostat and press the switch. Put the plastic cover
back.
Verify the causes of the overheating! If it happens again, check the installation
and function of the pumps and safety devices!
8.5.2.
Restart the burner after an error
1. Turn off the burner by using the electric switch the burner is connected.
2. Open the boiler's door and check the burner tube.
3. Remove any ashes and impurities from burner fire chamber.
4. Close the door and switch on the controller by using the electric switch the burner is connected
5. By pressing the button “MODE/ “ once changes the operation from “Stop” to “ignition”.
By pressing the button “MODE/ “ changes the operation from “Ignition” to “Automatic"