THERMOSTAHL MULTIPLEX MCL Instruction Manual Download Page 8

Type 

HL 

Power 

Oper. 

Pressure 

Water 

content 

Heating 

surface 

Dimension 

of feeding 

door 

Max 

wood 

length 

Silo 

Volume 

Motor 

Ventilator 

kW 

Mcal/h 

bar 

lit 

m

2

 

[mm] x 

[mm] 

mm 

lt 

kW 

m

3

/h 

23 

23 

20 

85 

710 x 380 

500 

350 

0.18 

250 

35 

35 

30 

2

 

95 

3.4 

710 x 380 

600 

350 

0.18 

250

 

47 

47 

40 

2

 

105 

3.5 

710 x 380 

400 

350 

0.18 

250

 

58 

58 

50 

2

 

120 

730 x 500 

500 

370 

0.25 

350 

69 

69 

60 

2

 

140 

4.5 

710 x 380 

600 

370 

0.25

 

350

 

81 

81 

70 

2

 

140 

710 x 380 

700 

370 

0.25

 

350

 

93 

93 

80 

2

 

160 

5.5 

710 x 380 

800 

370 

0.25

 

500

 

116 

116 

100 

2

 

200 

710 x 380 

900 

370 

0.25

 

500

 

140 

139 

120 

2

 

260 

710 x 380 

800 

600 

0.37

 

500

 

160 

162 

140 

2

 

290 

370 x 625 

900 

600 

0.37

 

780 

190 

186 

160 

2

 

330 

10 

370 x 625 

1000 

600 

0.37

 

780 

210 

209 

180 

2

 

360 

11 

370 x 625 

1150 

600 

0.37

 

900 

230 

233 

200 

2

 

420 

13.5 

370 x 625 

1400 

600 

0.37

 

900 

260 

256 

220 

2

 

450 

14 

370 x 625 

1400 

600 

0.37

 

900 

290 

291 

250 

3

 

620 

17 

370 x 625 

1100 

950 

0.37

 

1400 

350 

349 

300 

720 

21 

860 x 490 

1400 

950 

0.37

 

1400 

1400 

 

400 

407 

350 

820 

25 

860 x 490 

1600 

950 

0.37

 

1400 

460 

465 

400 

920 

29 

860 x 490 

1850 

950 

0.37

 

1400 

580 

581 

500 

1020 

33 

860 x 490 

2160 

950 

0.37

 

2600 

700 

698 

600 

890 

31 

860 x 490 

1300 

950 

0.37

 

2600 

750 

756 

650 

1100 

42 

1230x520 

1600 

950 

0.37

 

2600 

800 

814 

700 

1300 

51 

1230x520 

1800 

950 

0.37

 

3800 

870 

872 

750 

1450 

59 

1230x520 

2050 

950 

0.37

 

3800

 

930 

930 

800 

1600 

64 

1230x520 

2200 

950 

0.37

 

3800

 

1050 

1046 

900 

1800 

68 

1230x520 

2450 

950 

0.37

 

3800

 

1160 

1162 

1000 

2000 

72 

1230x520 

2650 

950 

0.37

 

3800

 

1400 

1400 

1200 

3500 

73 

1730x740 

2200 

1900 

00 

0.37

 

3800

 

1600 

1620 

1400 

3700 

89 

1730x740 

2700 

1900 

0.37

 

3800

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for MULTIPLEX MCL

Page 1: ...MULTIPLEX MCL INSTRUCTION MANUAL ver 1 1...

Page 2: ...tory The name THERMOSTAHL means GUARANTEE for the buyer THERMOSTAHL provides heating solutions for more than 20 years on the market The production experience and the expertise gives us the opportunity...

Page 3: ...TIVES SPECIFICATIONS 3 PREFACE 4 1 DESCRIPTION 5 2 DELIVERY TRANSPORT 5 3 FEATURES OF THE BOILER MULTIPLEX 9 4 BOILER LOCATION 12 5 CHIMNEY 14 6 BOILER ASSEMBLING 16 7 CONTROL PANEL 16 8 MAINTENANCE G...

Page 4: ...Electrical conections between burner and boiler Standard 763 Central heating boilers Minimum dimensions of the combustion chamber Standard 234 Central heating boilers Terminology nominal power techni...

Page 5: ...Familiarize yourself with its operations and controls and follow strictly the instructions given If you have any questions or you need more information about particular points concerning the THERMOSTA...

Page 6: ...is designed in such a way that all the surfaces that come in contact with the flame to be cooled by water including the grid where the ash and the remains of burning are The two ways of exhaust from t...

Page 7: ...e the boiler during transport on the transport means so as not to slip Consider seriously that the gravity centre is above the geometric centre That means there is need of a special care during transp...

Page 8: ...780 210 209 180 2 360 11 370 x 625 1150 600 0 37 900 230 233 200 2 420 13 5 370 x 625 1400 600 0 37 900 260 256 220 2 450 14 370 x 625 1400 600 0 37 900 290 291 250 3 620 17 370 x 625 1100 950 0 37 14...

Page 9: ...480 295 130 2 260 910 1600 1850 1900 810 1730 610 100 1570 930 1500 1480 295 130 2 290 1100 2000 2000 1840 1000 2250 830 150 1570 930 1250 1210 345 130 2 350 1100 2000 2000 2090 1000 2250 830 150 2160...

Page 10: ...ucing the number of ignition starts of the burner in case of adapting of a burner Reliability Energy savings Enviromental friendly Modern Design Solid Construc ion Easy maintenance Big fire box Large...

Page 11: ...d pipe that crosses the rear plate and the combustion chamber and which has an optimal length to ensure a better air intake The ventilator is controled by the control panel and the conection of the ve...

Page 12: ...ned in such a way that all its parts in touch with flames to be cooled by water The profile number and length of the smoke pipes are designed specially for a maximal exploitation of the exhausts The w...

Page 13: ...ance fireproof doors and without woods for windows The boilers having the caloric flow of 0 1 Gcal h can be located in rooms having other destinations in which it will be arranged an appropriate space...

Page 14: ...would be listed the work instructions that will consider the speciffic of the boilers in the room There will be also listed internal instructions concerning the operators task and the way of operatin...

Page 15: ...ds grass etc The cleaning of the chimney esspecially in the exit points from the boiler and the elbows where the exhaust gases change their course A clean chimney means a correct draught The insulatio...

Page 16: ...sons for malfunction of solid fuels boilers 1 Small active height of the chimney 2 Untight masonry of the chimney 3 Too narow masonry of the chimney 4 The existence of foreign parts or narowing of the...

Page 17: ...70 boilers we have only one cover for the sides For the other boiler series we have two or three covers for the sides 7 THE CONTROL PANEL Digital Electronic Controller PWC 1000 Operating instructions...

Page 18: ...maximum exhaust temperature that the fan power starts to decrease 08 IGNITION TIME Maximum time of the process ignition Fan power is determined only by the ignition air setting at this process 09 IGNI...

Page 19: ...ng Increased fuel consumption Increasing temperature of exhausts Carbon layers Reduced draught Maintenance instructions Disassemble the burner if necessary Open the doors Disassemble the turbulators f...

Reviews: