background image

CONTROLLER 

 

16 

 

5.4.

 

Error signals 

The  controller  automatically  recognizes  the  corresponding  error,  and  will  inform  the  user  by 
displaying the corresponding error code on the display. The errors are divided in two categories: 

5.4.1.

 

Errors 

Errors are minor importance faults during operation. By pressing the  Button 3 (MENU/OK)
the description of the error appears on the display. These minor errors do not stop the function 
of the boiler. When an error incures, the following message will appear on the display: 

 

 

 

5.4.2.

 

Alarms 

An alarm will be activated when a major safety issue will incure. When an alarm incures, the 
ALARM message will blink on the display, and an alarm code and description will appear. The 
following message will appear on the display:  

 

 

 

 

CODE 

MESSAGE 

SOLUTION 

A01 

Failed ignition 

Clean the grate from pellets and retry igntition 

A02 

No flame 

Fill the tank with pellets 

A03 

Tank overheating 

Check the fuel tank temperature sensor 

A04 

Exhaust temperature alarm 

Check the exhaust temperature sensor and the 
combustion settings 

A05 

Chimney block 

Check the chimney condition, clean from ash and 
possible obstacles 

A06 

Insufficient combustion air 

Clean the grate, the air intake, the chimney 

A07 

Open door 

Make sure the door is closed 

A08 

Exhaust fan damage 

Call service 

A09 

Exhaust temperature damage 

Call service 

A10 

Ignitor damage 

Call service 

A11 

Pellet feed damage 

Call service 

A13 

Controller damage 

Call service 

A15 

Pellet level alarm 

Check the fuel level in the tank 

A16  

Water pressure 

Assure correct pressure of the installation 

A18 

Water temperature overheating  Investigate the causes of overheating 

 

By pressing the Button 1 (MODE/ESC), an indication of the alarm cause will appear, according 
to the following table: 

MESSAGE 

DESCRIPTION 

Service 

Call the service for regular maintenance 

Ex. temperature sensor error 

The exhaust temperature sensor is damaged 

Water temperature sensor error  The boiler water temperature sensor is damaged 
Water pressure sensor error 

The water pressure sensor is damaged 

Water pressure out of limits 

The water pressure in the heating installation is out of 
limits 

e  s  c                  S  e  t   

<   

  E  r  r  o  r            >   

i  n  f  o    A  L  A  R  M    A  0  1   

Alarm description 

>   

Summary of Contents for COMPACT 25

Page 1: ...PELLET BOILER COMPACT INSTALLATION AND USER MANUAL VERSION 1 1 UPDATE 31 05 2019...

Page 2: ...requirements 5 3 3 Chimney 6 3 4 Air intake 7 4 INSTALLATION 8 4 1 Boiler connections 8 4 2 Return temperature protection 9 4 3 Filling the system 9 4 4 Electrical connections 9 5 CONTROLLER 10 5 1 G...

Page 3: ...f the appliance unless you have contacted the company and an authorized service contractor Only original accessories and spare parts must be used to ensure correct and safe function Make sure you resp...

Page 4: ...ith this boiler No other fuel is allowed to be used in the boiler The pellet is deposited in the fuel tank at the back of the boiler and then automatically fed through the feeder which is controlled b...

Page 5: ...st be placed on a horizontal plane with adequate mechanical resistance to support the boiler s weight The boiler can be installed in a special boiler room or inside the house The installation must be...

Page 6: ...recommended to have a 15 30o inclination upwards The connection with the boiler s chimney pipe must be air tight If the total route of the chimney pipe is more than 10 m it is recommended to use a 100...

Page 7: ...mbustion air intake of the boiler is absorbed externally through an air intake pipe that must be installed as seen above The air intake pipe must be protected with a grate according to UNI 10683 The a...

Page 8: ...nded for maximum working temperature 85o C and maximum pressure 3 bar Safety valve is not installed inside the boiler it must be installed externally and connected to the drainage External thermostat...

Page 9: ...k that all the connections are tight and there are no water leakages Make sure that during this period no pressure drop appears After firing the boiler make sure the network functions properly at work...

Page 10: ...avigation 5 Controller ON OFF button exit to main menu IR Remote control receiver D Display 5 2 Operation functions After switching the boiler on from the main switch at back side press the controller...

Page 11: ...boiler will automatically adjust the power level according to the temperature settings chosen and the signal from the room temperature sensor if activated If the room thermostat contact is open the bo...

Page 12: ...selected If the room thermostat contact is open the boiler will go to minimum power and will shut down after a preset time In ECO mode on the display will appear the following message By pressing the...

Page 13: ...on 5 ON OFF at any point to exit to the main window 5 3 1 Water temperature The water temperature for heating and sanitary mode can be set at this menu On the display the following message will appear...

Page 14: ...the corresponding parameters P1 Start and P1 Stop as well as the air temperature water temperature and power level settings for this time interval Finally with the P1 day parameter the day of the wee...

Page 15: ...or deactivates the Eco mode The Back Light parameter sets the permanent lighting of the display On or for a certain amount of time after pressing a button 01 1000 s The tones parameter will enable the...

Page 16: ...t temperature sensor and the combustion settings A05 Chimney block Check the chimney condition clean from ash and possible obstacles A06 Insufficient combustion air Clean the grate the air intake the...

Page 17: ...ressed the Button 5 ON OFF for 2 seconds until the message IGNITION will appear on the display 6 2 2 Start up by the room temperature sensor The boiler will automatically start when the room temperatu...

Page 18: ...iven that the AUTO or ECO mode is chosen and the boiler is activated by the main electrical switch 7 1 4 Stop by SLEEP mode The boiler will automatically stop according to the SLEEP mode settings see...

Page 19: ...en the external door cover and the internal boiler door Scrape the ashes from all the surfaces Empty the ashes from the grate and make sure all the holes are clear of ashes and other obstacles The cle...

Page 20: ...20 THERMOSTAHL ROMANIA HEATING SYSTEMS S R L DRUMUL OSIEI 57 59 sector 6 Bucharest 062395 Romania www thermostahl ro...

Reviews: