CONTROLLER
12
5.2.2.
MANUAL mode
In mode MANU, the power level of the boiler can be manually selected. The room thermostat
doe not function in this mode. In MANU mode on the display will appear the following
message:
By pressing the Button 2 (-) power level can be adjusted from Fire 1 to Fire 5. By keeping
pressed the Button 2 (-), the following message will appear on the display and the same setting
can be adjusted here through the Buttons 2 (-) and 4 (+):
The use of MANUAL mode is restricted for service settings and should not be
used in normal operation.
5.2.3.
ECO mode (recommended)
In mode ECO, the power level of the boiler can be manually selected. If the room thermostat
contact is open, the boiler will go to minimum power, and will shut down after a preset
time. In ECO mode on the display will appear the following message:
By pressing the Button 2 (-) the room temperature can be adjusted from 5 to 35
o
C. By keeping
pressed the Button 2 (-), the following message will appear on the display and the same setting
can be adjusted here through the Buttons 2 (-) and 4 (+):
If the room temperature sensor is deactivated, the message Temp 0 will be shown instead, the
set point for mode ECO will be the water temperature selected, and the room temperature sensor
will behave as an ON/OFF signal.
By pressing the Button 4 (+) the power level can be adjusted.
M o d e M A N
U M e n u
F i r e 2 3 °C
F a n A
e s c
O k
- F i
r
e +
M o d e E C O
M e n u
T e m p 2 3 °C
F a n A
e s c 2 3 °C
O k
- T e m p e
r . +