CONTROLLER
15
5.3.5.
Settings
In this menu, the user can make general configuration settings of the device. On the display the
following message will appear:
MENU
PARAMETER
VALUE RANGE
RECOMMENDED
SETTING
Settings
Language
En-It-Fr-Es-Gr
En
Eco
On / Off
On
Back Light
01-1000 s
Accordingly
Tones
On / Off
On
o
C /
o
F / Auto
o
C /
o
F
o
C
Recipe
Pellet Temp.
States
-5...+5
0
Pellet Power
States
-5...+5
0
Air Flow Temp.
States
-10...+10
0
Air Flow Power
States
-10...+10
0
Thermosat Activation
On / Off
Accordingly
Charge
Pellets
Activation
Ok
Cleaning
Activation
Ok
Start
Pump
Activation
Ok
The Eco parameter activates or deactivates the Eco mode.
The Back Light parameter sets the permanent lighting of the display (On) or for a certain amount
of time after pressing a button (01-1000 s).
The tones parameter will enable the keyboard sound when pressing a button.
Through the Recipe parameters, the pellet feeding and air supply can be adjusted individually
for the ignition mode (Temp. States) and the function mode (Power States). For every unit
interval, a 2,5% modification is performed to all the power levels.
Through the Thermostat parameter, the integrated room temperature sensor can be activated
(On) or deactivated (Off).
The last three parameters are used to manually activate the individual devices (feeder,
cleaning motor, pump), and must be used only during service by authorized technician.
e s c S e t
<