SERVICE AND MAINTENANCE
26
Remove the whole feeder together with the bearings and supporting disk (see Fig 16).
Fig 16.
Removing the upper axis
When putting back together, it is absolutely necessary to put the rubber gasket at
its position!
REMOVING THE LOWER AXIS
Remove the protection cover of the transmission system.
Remove the two gears from the axes by unscrewing the headless inserted screws keeping
them in place.
You do not need to unmake the chain! Remove them all together with
the chain.
Unscrew the four nuts keeping the motor in place and remove it (see Fig 17).
Fig 17.
Removing the lower axis
Remove the support disk and the feeder.
When putting back together, it is absolutely necessary to put the rubber gasket at