background image

 

HL-800K Infrared Laser Thermometer User Manual 

 

Thermosense Limited 

T: +44 (0)1628 531166 

E: 

[email protected]

 

W: www.thermosense.co.uk 

Page 2 

TABLE OF CONTENTS 

INTRODUCTION ........................................................................................................ 3

 

FEATURES ................................................................................................................ 3

 

WIDE APPLICATION RANGE .................................................................................... 3

 

SAFETY ..................................................................................................................... 3

 

DISTANCE & SPOT SIZE .......................................................................................... 4

 

SPECIFICATIONS ...................................................................................................... 4

 

FRONT PANEL DESCRIPTION ................................................................................. 5

 

INDICATOR ................................................................................................................ 5

 

BUTTONS .................................................................................................................. 5

 

MEASUREMENT OPERATION .................................................................................. 6

 

BATTERY REPLACEMENT ....................................................................................... 7

 

NOTES ....................................................................................................................... 7

 

MAINTENANCE & CLEANING .................................................................................. 8

 

 

 

 

 

 

 

 

 

 

Summary of Contents for HL-800K

Page 1: ...HL 800K Infrared Laser Thermometer 50 C to 800 C 13 1 ratio User Manual...

Page 2: ...s thermosense co uk W www thermosense co uk Page 2 TABLE OF CONTENTS INTRODUCTION 3 FEATURES 3 WIDE APPLICATION RANGE 3 SAFETY 3 DISTANCE SPOT SIZE 4 SPECIFICATIONS 4 FRONT PANEL DESCRIPTION 5 INDICAT...

Page 3: ...urement Type K temperature Measurement Unique flat surface modern housing design Built in laser pointer Automatic Data Hold Automatic Power Off switch Emissivity Digitally adjustable from 0 10 to 1 0...

Page 4: ...F 20 to 200 C 4 to 392 F 1 5 of reading 2 C 3 6 F 200 to 538 C 392 to 1000 F 2 0 of reading 2 C 3 6 F 538 to 800 C 1000 to 1472 F 3 5 of reading 5 C 9 F Response time Less than 1 second Spectral resp...

Page 5: ...DICATOR 1 Data hold 2 Measuring indication 3 Emissivity symbol and value 4 C F symbol 5 Auto obtain Emissivity 6 Lock and laser on symbols 7 High alarm and low alarm symbol 8 Temperature values for th...

Page 6: ...while the unit is locked on the laser and backlight will be turned on if they have been activated When the unit is locked on the backlight and laser will remain on unless it is turned off using the La...

Page 7: ...ty will be incorrect It s necessary to obtain a new emissivity Note Measurement Considerations Holding the meter by its handle point the IR Sensor toward the object whose temperature is to be measured...

Page 8: ...vity of 0 95 pre set in the unit Inaccurate readings will result from measuring shiny or polished metal surfaces To compensate cove the surface to be measured with masking tape or flat black paint All...

Reviews: