Pag. 8 Tot 27.
THERMOSALD UPSCR_M_V3
08/2000
2.3 BOARD-PANEL CONNECTING CABLE DIAGRAM
Board side
Panel side
Canon 9-pin male connector
Canon 9-pin female connector
1 + 5V
___________________________________________
1 + 5V
2 0V
___________________________________________
2 0V
3 Data
___________________________________________
3 Data
4 Clock
___________________________________________
4 Clock
5 Key
___________________________________________
5 Key
6 Key
___________________________________________
6 Key
7 Key
___________________________________________
7 Key
8 Key
___________________________________________
8 Key
2.4 POWER TRANSFORMER DIMENSIONS
2.5 PROTECTIVE DEVICE DIMENSIONS
•
Use a 8 x 0.22 multi-core screened cable. The screen must be wired to both connectors. It is advisable to run this cable
away from transformers or unscreened power leads.
PRIMARY WINDING: 0/230/400 Vac
(With a 400 Vac primary winding, use a 230 Vac autotransformer
or a 400/230 external transformer to supply the synchronised logic system)
CORE: EARTHED
SECONDARY WINDING: DETERMINED BY USING THE FOLLOWING FORMULA :
TRANSFORMER RATED V = R x RATED I
( RATED I = 30 AMP. FOR TEMPERATURE CONTROLLER UPSCR10030, UPSCR10045
RATED I = 60 AMP. FOR TEMPERATURE CONTROLLER UPSCR10060, UPSCR10090
BAND RESISTANCE R = DETERMINED BY TAKING DIRECT READINGS AT THE ENDS OF THE BAND (OR
CALCULATED BY REFERRING TO THE CHART IN THE BLOCK BELOW, CHAPTER 2.6)
SUPERIMPOSED WINDINGS
ELECTRICAL SPECIFICATIONS:
THE VOLTAGE IN THE SECONDARY WINDING CAN BE STEPPED UP 1.6 TIMES (MAX.) IN ORDER TO
INCREASE THE SEALING SPEED.
GREEN
RED
WHITE
YELLOW
ORANGE
BROWN
BLACK
BLUE