THERMOSALD UPSCR_N_V5 - OPERATOR MANUAL - Rev. 2006 / 07
Page N. 8
- Tot: 18
4 –Press the keys 1 + 4 (down + reset) and, at the same time, power on the thermoregulator
4 - Release the keys 1+4 (down+reset)
5 – Display = “ P H A S ”
On the display appears “ P H A S ” to mean that logic and power supplies phase control is in progress (if logic and power
supplies are not on the same phase, “ F 0 8 3 “ fault signal is sent).
5 – Wait
6 – Display = “ V O L T ”
On the display appears “ V O L T ” to mean that TRASFORMER SECONDARY VOLTAGE control is in progress (this
voltage must be between TRASFORMER RATED VOLTAGE and TRASFORMER MAXIMUM VOLTAGE).
6 – Wait
4
– Display = “ V 0. 5 0 ” -> “ V 1. 1 0 ” - USE FACTOR
On the display appears “ V ” followed by a number that informs if thermoregulator is well used or not: the right value are
included in the range V 0.6 – V 1.0; absolute maximum rating V 1.3.
V 1.0 means active current 45A (for model 30A), 90A (for model 60A), 135A (for model 90A)
7 – Wait
8 – Display = “ V D I P ” blinking
On the display blinks “ V D I P ” to remember that SW+ / SW- dip switch must be set (see CALCULATION TABLE and
DIP SWITCH SW+ / SW- TABLE).
8 - Press the RESET key
9 – Display = “ T 0 2 0 ” = 20 DEGREES – Set gripper jaws temperature or wait
(“ T 0 3 0 ” = 30 DEGREES from software release V4.9)
On the display appears the ambient (gripper jaws) temperature set on the thermoregulator.
In applications where a great precision of temperature is necessary, it is possible change this parameter and set it with the
actual gripper jaws temperature, simply pressing keys DOWN / UP.
9 - Wait
- 4 blocks appear on the display; the reset procedure begins; release keys
down + reset (1 + 4).
- Thermoregulators leave our factory in reset state, then at power on 4 blocks
always appear and reset procedure begins.
- Whenever an operator needs to repeat reset procedure, he can keeps keys 1
+ 4 (down + reset) pressed 6 + 8 seconds untill on the display the 4 blocks
appear and the reset procedure begins.