4.2 – SETTING THE PRE-HEATING AND/OR SEALING TEMPERATURES
1 – Press the keys 3+4 (T/I+RESET) for 3 seconds
The PREHEAT led on the panel start flashing and indicate the set pre-heating temperature.
2 – Press the keys UP or DOWN to change the temperature of pre-heating.
3 – Press the key RESET to switch to the temperature of sealing changing.
The WELDING led on the panel start flashing and indicate the set sealing temperature.
4 – Press the keys UP or DOWN to change the temperature of sealing.
5 – Wait 3 seconds to leave temperature setting.
4.3 – WRITING DOWN THE START UP DATA CARD
Write down the START UP DATA CARD – PAG. 1, ANNEX G
If any machine or setting data is modified, write down also START UP DATA CARD – PAG. 2.
That above lets to record start up data in the documentation of the machine; it will be useful for future verify and for starting
up of the next machines, so it will be easer to do and all machine will be equal.
4.4 - SPECIAL FUNCTION ENERGY CONTROL
•
CAN BE PERFORMED ON ALL MACHINES HANDLING SLIGHTLY FLAMMABLE MATERIAL; THIS
INCREASE REDUNDANCY AND AUTO-CONTROL THEREBY MAKING THE SYSTEM SAFER TOO
(BEFORE GOING ON, GET IN TOUCH WITH OUR TECHNICAL OFFICE FOR INSTRUCTIONS)
1 - Enter the machine data
F = 1 to Enable the control for the pre-heating procedure
F = 2 to Enable the control for the heat-sealing procedure
F = 3 to Enable the control for the pre-h heat-sealing procedure
2 - Pre-heat for 10 seconds
The thermoregulator acquire the power supplied in pre-heating.
3 – Start the machine running with the bags loaded
The thermoregulator acquire the power supplied in sealing.
When acquisition phase is finished, if thermoregulator detects a power on the bag out of tolerance stop in emergency.
In the case of slightly flammable materials, the machine builder must pay much attention to applications and take
right solutions for safety.
NOTE – Each time the pre-heating and sealing temperature or some machine data are changed, an automatic data
acquisition needs to be performed.