4. Installation cased (2 ducts).
✓
Room at minimum frost free (T > 1°C).
✓
Parameter « Duct» to be set « Exterior/Exterior »
✓
Recommended room : living area (the heat loss of the water heater
remains in heated area), close to external walls. Avoid installation of water
heater and/or ducts near to sleeping rooms.
Examples :
•
Washing room,
•
Storage room,
•
Cupboard in entry area.
Keep a free space of 450 mm in front of electric to allow easy access for maintenance.
Respect the maximum length of ducts. Use insulated rigid ducts.
Plan grids at air entry and exit to avoid intrusion of objects or animals.
Attention, entry or exit grids with manual closing device are forbidden.
Exterior/Exterior
600mm
mini
100mm
mini
Installation
37
UK