Overview
Installation
Operation
Service, Maintenance and Repair
If the absence mode cannot be used it could be necessary to drain the water heater if the device is switched
off. Proceed as follows:
1. Advice to the user.
The device has to be disconnected from mains before opening the cover.
Maintenance
Warranty
Switch off power supply.
Open a hot water tap.
Close the cold water inlet.
Open the drain valve on the
security group.
❶
❸
❷
❹
In order to maintain the performances of your water heater, we advice to service it regularly.
2. Service.
By the USER :
What
When
How
Security group
1 to 2 times per month Operate the safety valve.
Check that water evacuation is ok.
General
1 time per month
Check external shape of your device : no Error code
displayed, no leakage on the connections...
By the INSTALLER :
What
When
How
Ducts
1 per year
Check if the device is ducted.
Check if the ducts are well positioned and not
deformed.
Condensates evacuation 1 per year
Check the cleanness of the condensates evacuation
tube.
Electric connections
1 per year
Check that any internal and external cable connections
are not loose and that all connectors are plugged in.
Electric backup
1 per year
Check the correct function of the electric backup by
measuring the power.
Scaling
Every 2 years
If the supply water is hard clean the deposited scale.
What
When
How
Thermal exchange of the
heat pump
Every 2 years
Check the correct working of the heat pump.
Components of the heat
pump
Every 2 years
Check the ventilator operation on it’s 2 speeds and the
hot gas valve.
Evaporator
Every 2 years
Clean the evaporator with a nylon brush and products
neither scratching nor corrosive.
Refrigerant
Every 5 years
Check the refrigerant quantity.
By the REFRIGERATION ENGINEER :
46
UK
Summary of Contents for 266002
Page 2: ......