17
A
B
C
D
E
F
G
H
I
The picture of the LCD to the right illustrates the Y151 in “Ready” mode.
A: Illuminated green LED indicates the power is “ON.”
B: Illuminated green LED indicates the heat is “ON” and rising to operating temperature.
Flashing LED indicates the machine has reached operating temperature.
C: Illuminated red LED indicates label is ready to be sealed.
D: Illuminated red LED indicates the machine is sealing.
E: Machine Operating Temperature icon: Temperature in either Celsius or Fahrenheit. The
picture to the right shows the machine is operating at the factory setting 176° C or 349° F.
F: Sealing Time- The nominal sealing time is 2.7 seconds. An optional 4.8 second sealing time is
available for thick, damp or dirty objects.
G: Operation mode: Label Quantity, Single Label or Continuous.
J
K
H: Total Production Counter- Number of labels sealed since the machine was installed. The
continuous counter cannot be reset.
I: Bundle Quantity- Number of labels to be sealed per bundle. Counter will count downward
from the number placed into the Bundle Quantity queue by the machine operator.
J: Text Entry Line- 5-12 alpha-numeric characters can be entered to be printed on labels.
K: Daily Production Counter- Number of labels sealed in the time in which the machine has been
operating. Resets after machine is switched off.
L: Label Length- NL stands for Normal Length. Extra Length “EL” is available to the machine
operator as well.
L