6. Troubleshooting
Failure
Possible Causes
Solution
Not connected to outlet
No line power to outlet
Fuses blown in Power Entry
Module
Check fuses in Power
Entry Module
Leak in Air Supply Hose
Repair or replace
Dust or water in air lines,
Regulator or Solenoid Valve
Disassemble and clean
Insufficient air presure
Check, seal and adjust Air
Filter Press/Reg
Press Arm Limit Switch defective
Check wiring or replace
switch
Solenoid Valve not engaged
Check wiring and air leaks
at fittings. Replace
Solenoid
No power to machine
Check outlet and fuses
Heater Element defective
Temperature Sensors defective
Solid State Relay defective
Main Controller Board defective
Error Detected:
Heater Defective
Defective Heater Element
Replace
Error Detected:
PT 1600
Defective
Defective Temperature Sensors
Replace
Temperature settings have been
changed
Reset temperature
settings
Temperature sensors are
defective
Replace sensors
Check Outlet
Replace
Sealing pressure
fluctuates
Machine does
not function
Machine does
not seal
No Heat
Temperature too
high or too low