4

11. 

Mount junction box base on expediter. 
Make sure to align slots to properly 
orient junction box base. Tighten nut 
with Terminator-LN-Tool. If mounting 
horizontally, threaded gland holes must 
face downward.

12. 

Install M25 power gland (order 
separately) and M25 blind plug.

13. 

Install power cable.

14. 

Install electronic control module and 
complete system wiring. Terminal set 
screws shall be tightened to a torque 
value of 1,4 Nm (12,4 lb-in). See page 5 
for wiring details. Set modules electronic 
control and/or control limiter at desired 
setpoints.

16. 

Use screwdriver to ratchet on junction 
box lid. Lid will rotate 30 degrees. Install 
junction box lid and twist hand tight. 
Insert screwdriver into ratchet slots 
located on side of junction box base.

17. 

Lid latch mechanism fully engaged. To 
remove lid, repeat step 16 but in the 
opposite direction.

The Heat Tracing Specialists

®

15. 

Use the rotary switches for settling 
Control and Limit Temperature, 
Celsius or Fahrenheit and Auto or 
Manual reset (Control switches on 
Type "C", Limiter switches on Type 
"L" and both on Type "CL").

Terminator

TM

 ECM-P-XP

 

INSTALLATION PROCEDURES

1725        II 2 GD  Ex eb mb [ib]ib IIC T4, Ex tb IIIC T135°C
               SIRA 12ATEX5239X

IP66

-60

°

C  

  Ta 

  + 55

°

C

IECEx SIR 12.0103X Ex eb mb [ib]ib IIC T4, Ex tb IIIC T135°C

PN 27673

D

o n

ot o

pen

 while

 energized. See installa

tion

 in

str

uc

tio

ns

Te

rm

inator EC

M

 

Fo

r u

se

 as

 an

 adj

ustable

 electronic c

ontro

l m

od

ule

10. 

Fix expediter, RTD, and lead wire to 
pipe.

Summary of Contents for Terminator ECM-P-XP

Page 1: ...ib IIC T4 Ex tb IIIC T135 C PN 27673 D o not open while energized See installation instructio n s T e rminator EC M F o r u s e as an adjustable electronic control m o d u l e TheHeatTracingSpecialists TerminatorTM ECM P XP Electronic Control Module INSTALLATION PROCEDURES For Connection 1 2 Heating Cables Applications ...

Page 2: ...e energize all power sources before opening enclosure Avoid electrostatic charge Clean only with a damp cloth Keep ends of heating cable and kit components dry before and during installation Minimum bending radius of heating cable is 32 mm except HPT is 57 mm and FP is 19 mm Individuals installing these products are responsible for complying with all applicable safety and health guidelines Proper ...

Page 3: ...with grommet provided in PETK 3 ECM 4 Slide expediter toward pipe and route cable through support base entry 8 Terminate cable with appropriate PETK termination kit Refer to PETK installation instructions 9 Push excess cable back through expediter Tighten cap securely Tape cable expansion loop to pipe 6 Mount expediter to pipe using pipe band Do not band over cable 7 Cut off end of cable Terminato...

Page 4: ...nstall junction box lid and twist hand tight Insert screwdriver into ratchet slots located on side of junction box base 17 Lid latch mechanism fully engaged To remove lid repeat step 16 but in the opposite direction The Heat Tracing Specialists 15 Use the rotary switches for settling Control and Limit Temperature Celsius or Fahrenheit and Auto or Manual reset Control switches on Type C Limiter swi...

Page 5: ...ble Layout Tips Insert two cables into expediter Note For HPT and FP cable exchange grommet in Terminator with grommet provided in PETK 3 ECM Wiring Details Connection 1 or 2 Heating Cables L L N N C NO NC Comm Port Alarm Relay Main supply Heater output B B A A B B RTD Limiter Sensor RTD Controller Sensor GND 1 2 TerminatorTM ECM P XP INSTALLATIONPROCEDURES ...

Page 6: ...on jusqu au point de blocage 17 La sécurité de blocage est complètement engagée Pour ouvrir le boîtier répéter l étape 16 mais dans l autre sens de rotation Deutsch Terminator ECM P XP Elektronisches Regelmodul INSTALLATIONSANWEISUNG Für Temperatursteuerung anschluss 1 bis 2 Heizkabel Warnhinweise Wegen der Risiken eines Stromschlags eines Funkendurchschlags oder eines Feuers die durch Produktbesc...

Page 7: ...s calefactores Advertencias Debido al riesgo de descargas eléctricas arcos eléctricos y fuego causados por daños en el producto o incuorrecta manipulación instalación o mantenimiento se requiere proteger el circuito mediante un diferencial La instalación debe cumplir con los requisitos de Thermon incluyendo el estándar PN 50207U para sistemas Ex y debe instalarse acorde a las regulaciones según la...

Page 8: ...erdere kabels 2 Voer de RTD voeler s in het doorvoerrubber Trek niet aan het uiteinde van de RTD voeler als deze door het doorvoerrubber in de opvoersok doorgevoerd wordt Trek aan het draadgedeelte de voeler door 3 Steek de kabel door het rubber en de opvoersok heen Zorg ervoor dat de knooppunt in de verwarmingskabel betreffende HPT and FP zich buiten de voet bevinden Let op Voor HPT en FP dient h...

Reviews: