88
P
ar
am
et
er
L
is
t
18
BIT LOGIC SETTING
INSTRUCTION FOR H22
(see above)
BIT 3 AND BIT 2 set to “HIGH”
BIT 1 AND BIT 0 set to “LOW”
19
H23
Allowable over current during speed search (80-200%).
200
precent of FLA
20
H26
Sets number of allowable restart attempts after a fault.
5
restart attempts
21
H27
Sets the time between restart attempts.
15
seconds
22
H31
Sets the number of motor poles.
2
poles
23
H33
Sets the motor Full-Load-Amps (FLA).
11.40
amperes
24
H36
Sets the motor operational efficiency.
90
percent
25
H77
Sets the soft starer fan activation trigger.
1
for during operation
26
H93
Sets factory defaults for the soft starter.
*CAUTION* Setting this can result in improper heater operation,
damage to the equipment , and/or potential safety hazard.
1
to set factory defaults
27
How to Lock the device to prevent the parameters from being changed (H95)
Step
Note
Keypad Display
1
Move to H95 code.
H95
2
Press Enter (
)
UL
3
Parameter value can be changed to UL (Unlock) status.
UL
4
Press Enter Key (
)
0
5
Enter the password created in H94 (eg.: 123)
123
6
Press Enter Key (
)
L
7
Parameter value cannot be changed in L (Lock) status.
L
8
Press Enter Key (
)
H95
How to Unlock the device to change parameters from being changed (H95)
Step
Note
Keypad Display
1
Move to H95 code.
H95
2
Press Enter (
)
UL
3
Parameter value cannot be changed in L (Lock) status.
UL
4
Press Enter Key (
)
0
5
Enter the password created in H94 (eg.: 123)
123
6
Press Enter Key (
)
L
7
Parameter value can be changed to UL (Unlock) status.
L
8
Press Enter Key (
)
H95
Summary of Contents for HELLFIRE 905