SOFT-STARTER DESCRIPTION

1. 

The Sinus M 001 2S/T BA2K2 VFD (Variable Frequency 

Drive) is an optional component included in the 
Hellfire 905 design to reduce inrush and start-up 
amperage.

2. 

The soft starter is configured to reduce start-

up amperage to not exceed the motor full load 
amperage under most start-up conditions.

3. 

The soft starter is coupled to a 240VAC 3 phase motor. 

It converts the 240 VAC 1 phase supply to 240 VAC 3 
phase to reduce motor start up acceleration.

4. 

The soft starter also serves as the motor overload 

protection.

5. 

The soft starter also provides additional protection 

features such as:  Over voltage, Under voltage and 
Phase loss.

CAUTION

CAUTION. 

The soft starter’s purpose is to reduce 

inrush and start up currents, it should not be used 
to adjust the blower speed.  Changing or 
modulating the blower speed may create a safety 
hazard and/or damage the the equipment.

TECO Westinghouse SINUS M 001 2S/T BA2K2 VFD

Summary of Contents for HELLFIRE 905

Page 1: ...istered trademark of Thermon Inc Copyright 2021 All rights reserved 2020 HELLFIRE 905 Gas Fired Railway Switch Heater Soft starter Operation and Parameters TECO Westinghouse Sinus M 001 2S T BA2K2 Par...

Page 2: ...TABLE OF CONTENTS A Important Notices and Warning Symbols 4 B Soft starter description 6 C Display 6 C 1 Operations and Display Format 6 C 2 Navigation 7 D Parmameter list 8 E Troubleshooting 10...

Page 3: ...ns who can understand and follow the instructions should use or service this heater If you need assistance or heater information such as an instructions manual label etc Contact the manufacturer Mises...

Page 4: ...la chambre de combustion ou l entr e d air Heater can start automatically Exercise caution when in close proximity Attention le radiateur peut d marrer automatiquement Faire preuve de prudence pr s d...

Page 5: ...to a 240VAC 3 phase motor It converts the 240 VAC 1 phase supply to 240 VAC 3 phase to reduce motor start up acceleration 4 The soft starter also serves as the motor overload protection 5 The soft st...

Page 6: ...igation Up and Down Buttons C 2 Navigation The default display parameter on the soft starter is the output frequency When the heater is off this will read 0 00 When the heater is operational this will...

Page 7: ...This parameter is a percentage of the FLA set up in parameter H33 130 percent of FLA 8 F58 Sets the overload trip time This value sets the time it takes for the soft starter to disable the motor if it...

Page 8: ...his can result in improper heater operation damage to the equipment and or potential safety hazard 1 to set factory defaults 27 How to Lock the device to prevent the parameters from being changed H95...

Page 9: ...Trip Start up supply voltage sag resulting in high motor current To decrease the likelihood of this reoccurring adjust the heater Delay Start potentiometer to eliminate synchronous starting with other...

Page 10: ...NOTES NOTES...

Page 11: ...NOTES NOTES...

Page 12: ...g defects apparent within 30 days from the date of installation The Company neither assumes nor authorizes any person to assume for it any other obligation or liability in connection with the product...

Reviews: