22
ThermoFLUX
Minitherm -
2.
FUNCTION STAND-BY SET OFF
In the case that function STAND BY is not activated (OFF) , and that
connection for the room thermostat is not overbridged, stove will always work
in power 1 no matter which power is set.
In the case that function STAND BY is not activated (OFF), and connection for
room thermostat is overbridged (set in the factory) stove will work in the power
chosen by the user, and when desired temperature is reached will go into
modulation mode. Stove will shut down only if the temperature in the stove is
80 degrees C, and will start again when temperature drops down below desired
temperature.
5.3.5.2
STAND BY mode with room thermostat connected
1.
FUNCTION STAND-BY SET ON – room thermostat shuts down
stove
When room thermostat sends signal that desired temperature in the room is
reached (contact is open/temperature is reached) stove will shut down after
2 minute (factory settings- in the case that temperature in the room
changes all to prevent constant turning on and off of the stove) on display is
written
tOFF-WAITING REQUEST.
When room thermostat gives signal that room temperature is low (contact
closed/ temperature needs to be reached) stove will start ignition and on
display is written
tON.
Remark:
Stove functioning primarily depends on temperature of the air inside
of stove and factory settings inserted. If stove is in state of
WAITING
COOLING
(air temperature is reached), eventual request of the thermometer
will be ignored.
2.
FUNCTION STAND-BY SET OFF – room thermostat gives signal
to the stove to work in POWER 1
In the case that function STAND BY is not activated (OFF) stove will work in
power chosen by the user and when desired temperature is reached stove will
modulate (will not shut down but working power will change to lowest).
Stove will shut down only if temperature of the air in the system is 80 degrees
C, and on display is written
WAITING COOLING
. Stove will start again when
temperature in the system drops down below set temperature.
5.3.6
Option Buzzer
B
UZZER
is used in the case that user want to hear sound signal from the stove
in the case of activated alarm ( set ON ), or without sound signal ( set OFF ).
Summary of Contents for Minitherm
Page 2: ...2...
Page 17: ...17 ThermoFLUX Minitherm...
Page 18: ...18 ThermoFLUX Minitherm 5 3 1 Clock adjustments Clock adjustments can be done on following way...
Page 20: ...20 ThermoFLUX Minitherm Shema 2 Shema 3 Shema 4...
Page 39: ...39 ThermoFLUX Minitherm 13 EU Label...
Page 40: ...40 ThermoFLUX Minitherm...
Page 41: ...41 ThermoFLUX Minitherm...