background image

 

 

 

 

 

 

ThermoFLUX d.o.o., Bage br. 3, 70101 Jajce, Bosna i Hercegovina, Tel/Fax: 030–648-050 

 

www.thermoflux.ba

 

[email protected]

 

 

 

PELLET STOVE 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

USER AND MAINTENANCE MANUAL

Summary of Contents for Minitherm

Page 1: ...ThermoFLUX d o o Bage br 3 70101 Jajce Bosna i Hercegovina Tel Fax 030 648 050 www thermoflux ba tfinfo thermoflux ba PELLET STOVE USER AND MAINTENANCE MANUAL...

Page 2: ...2...

Page 3: ...Safety devices 8 3 Installation and commissioning of the stove 9 3 1 Conditions 9 3 2 Chimney and flue gas pipes 9 3 3 Minimum distances of the stove from wall and objects 10 4 Functional description...

Page 4: ...of stove 26 6 3 Stove power adjustments 26 6 4 Adjustment of air temperature 27 6 5 Modulation 27 6 6 Cleaning of FIRE POT 28 7 Cleaning and maintenance 29 7 1 Daily cleaning 29 7 2 Weekly cleaning 2...

Page 5: ...3 Technical changes ThermoFLUX continuously develops and improves its stoves The information in this version is correct at the time of going to press All details in this manual on standards and regula...

Page 6: ...aining the installation operation and maintenance specified by the manufacturer The user may only enter or change the operating values specified in this manual Any other entries will affect the stove...

Page 7: ...h this symbol can lead to serious injuries or to extensive material damage CAUTION Hand injuries Work on locations marked with this symbol can lead to hand injuries CAUTION Hot surface Work on locatio...

Page 8: ...pt ready to hand at the stove s installation location Pay particular attention to the applicable local standards and guidelines 2 5 Safety devices Stove is equiped with safety devices that in case of...

Page 9: ...ns must be fulfilled before the system is put into operation Turn OFF electrical power Check mechanical connections Check that all components are properly connected Check that all mechanical component...

Page 10: ...he cleaning of inner parts especially the horizontal parts Smoke pipe should be installed fixed It would be good to leave safety gates that could do the Minitherm r cleaning especially in their horizo...

Page 11: ...11 ThermoFLUX Minitherm 4 Functional description 4 1 General overview Accompanying material Tools for the pipeline and firebox cleaning Door key Power supply cable Instructions booklet Guarantee...

Page 12: ...working temperature o C 85 9 Max working pressure bar 2 5 10 Height to center of flue pipe mm 198 5 11 Depth mm 575 12 Width mm 480 13 Height mm 945 14 Color red black 15 Flue pipe diameter mm 80 16...

Page 13: ...ton Description 1 Increasing temperature and program functions adjusting days time 2 Decreasing temperature and program functions adjusting days time 3 Changing accepting program 4 ON OFF program exit...

Page 14: ...o increase or decrease heating by automatic adjustment of power If there is a need to increase power this is registered by regulation and regulation gives a signal to increase power by adding more pel...

Page 15: ...nt igniter starts to ignite pellet and suction fan is on and is making necessary underpressure needed for combustion When temperature sensor for flue gasses detects that temperature in the chimney has...

Page 16: ...16 ThermoFLUX Minitherm 5 3 Schematic representation of the menu control By pressing button SET we enter general menu...

Page 17: ...17 ThermoFLUX Minitherm...

Page 18: ...18 ThermoFLUX Minitherm 5 3 1 Clock adjustments Clock adjustments can be done on following way...

Page 19: ...nt times for ignition and shutting down of the stove This applies to all days in the week Scheme 2 2 WEEK PROGRAM in this mode we can set 4 four different times for ignition and shutting down In this...

Page 20: ...20 ThermoFLUX Minitherm Shema 2 Shema 3 Shema 4...

Page 21: ...y STAND BY mode is activated by pressing button SET and afterwards by pressing buttons 5 and 6 we choose desired item in the MENU 04 STAND BY MODE By pressing SET we are opening options ON or OF choos...

Page 22: ...nt constant turning on and off of the stove on display is written tOFF WAITING REQUEST When room thermostat gives signal that room temperature is low contact closed temperature needs to be reached sto...

Page 23: ...here is a big possibilty that there are some leftovers from pellet in it while spiral dispenser was filled Combustion chamber needs to be empty and then ignition process can be initiated 5 3 8 STATE O...

Page 24: ...FLUX Minitherm By pressing SET option for desired type of fuel is opened PELLET or WOOD Selection is made by buttons 1 or 2 After choosing of fuel type confirmation of selection is done by pressing bu...

Page 25: ...g things needs to be checked Silo needs to be filled with pellet Silo doors needs to be closed Combustion chamber basket needs to be cleaned Ash pot needs to be clean All doors on stove needs to be cl...

Page 26: ...ING FINAL Suction fan is working on maximum feeding of pellet is stopped 6 3 Stove power adjustments During working phase it is neccesary to set working power in which we want stove to work Adjustment...

Page 27: ...ory settings and it is not possible to set lower or higher temperature then above mentioned 6 5 Modulation When temperature in stove is near to set value regulation begins to modulate its work and cha...

Page 28: ...start process of ignition again 6 6 Cleaning of FIRE POT During its work stove has set timer for cleaning of combustion basket fire pot after certain time This phase is shown on display and work of t...

Page 29: ...out of the firebox to ensure a smooth flow of air necessary for efficient combustion Using safety gloves take the firebox out and empty its content into a fire resistant container Clean the holes in t...

Page 30: ...nto the firebox Close the door before ignition 7 3 Cleaning the tube heat exchanger We recommend cleaning of heat exchange tubes before cleaning of ash pot and braizer basket 1 Turn the stove off and...

Page 31: ...31 ThermoFLUX Minitherm 7 4 Cleaning the flue gas chamber Remove 4 pieces hexagonal nuts on top Remove side panels...

Page 32: ...ber Clean the sediments out of the tube heat exchanger using the vacuum cleaner Check if there is any ash left in the firebox or in the ash pan and clean them in accordance with the instructions given...

Page 33: ...x for Power 220 V 50 Hz Room thermostat Stove needs to be connected to el Power supply 220 V and 50 Hz through fuse of 6 10 A fast Room thermostat User has possibility to instal room thermostat in oth...

Page 34: ...llets Pellet igniter is defective replace it Contact Service Restart the stove NO PELET During operation of the stove flue gas temperature has decreased below the permitted values No pellets in the si...

Page 35: ...ctivated because the stove air temperature exceeded 95 C Wait for the stove to cool down and then unscrew the plastic cap and suitable tool to reset the switch It is possible that the pump is is out o...

Page 36: ...n be disposed on landfills for metal stove cover metal sheets feeding system except motor braizer basket Electronic components can be recycled Glass glass wool and plastic parts can be recycled on lan...

Page 37: ...to be done by authorised service or person authorised by ThermoFLUX or authorised importer distributor Stove must work in accordance with terms and conditions given in this manual Stove needs to be in...

Page 38: ...38 ThermoFLUX Minitherm 12 Technical personal List of technical personal and authorised distributers you can find on our web pages www thermoflux ba and www servis thermoflux ba...

Page 39: ...39 ThermoFLUX Minitherm 13 EU Label...

Page 40: ...40 ThermoFLUX Minitherm...

Page 41: ...41 ThermoFLUX Minitherm...

Page 42: ...42 ThermoFLUX Minitherm User manual MINITHERM LCD EN ThermoFLUX d o o Bage br 3 Jajce Bosnia and Herzegovina Tel fax 387 30 657 100 www thermoflux ba...

Reviews: